7.3.7
OPTIONS
The OPTIONS menu allows setting the network address number of the LA4 within a network, the input signal source
(analog or digital), the delay unit, and the contrast of the LCD screen. It also gives real-time display of each amp channel
temperature and RMS output voltage as well as displaying data like MAC ADDRESS and firmware and onboard preset
library versions.
By selecting the OPTIONS menu and rotating the encoder wheel the user can have access to 9 different menu pages
(see Figure 22). All 9 menu pages are fully detailed in the next sections.
Figure 22: OPTION menu pages
NETWORK ADDRESS
110
INPUT MODE
ANALOG
PRESET VERSION
V1.1
Reboot the LA4
OK
ESC
NETWORK ADDRESS
> 123 <
OK
ESC
NETWORK ADDRESS
123
DELAY UNIT
ms
OK
ESC
OK
ESC
DELAY UNIT
> Meters <
DELAY UNIT
Meters
MONITOR TEMP (°C)
65 64 65 63
OUT RMS VOLTAGE
36 33 35 34
CONTRAST SCREEN
100 %
OK
ESC
OK
ESC
CONTRAST SCREEN
> 35 % <
CONTRAST SCREEN
35 %
IDENTITY NUMBER
00:1B:92:01:00:16