LA4_UM_ML_1.1
w w w . l - a c o u s t i c s . c o m
17 en
EN
6.5
On/Off Switch
When the controller is switched on (Figure 8), it will go thru a 20 seconds start-up procedure of internal tests as
described in section 7.4.1. When the LCD shows the main screen the controller is ready for use (see section 7.2).
When the amplified controller is switched Off, the LCD flashes the following message ‘‘POWER OFF’’ for several
seconds until complete shut down.
Note:
If the power is lost while the amplifier is switched on, it will restart automatically once the power has been
restored and reboot to the exact same state then prior the power loss.
If the On/Off switch is On and nothing is shown on the LCD display while the L-Net LED is lit, the controller is in
Stand-by Mode, under the control of the LA NETWORK MANAGER application, and cannot be operated via the front
panel. In this particular case rebooting the unit by switching it off and on again will cancel the Stand-by Mode.
The On/Off switch does NOT disconnect the amplified controller from mains.
Figure 8: The On/Off switch
On
Off