Rigging procedures
Adding a pull-back under Kiva II
type of deployment
own array
rigging accessory
KIVA-PULLBACK
1 x Ø12 mm shackle WLL 1 t
min number of operators
1
Space between lifting points
The space between the two lifting points must be aligned with the array pickup points.
The deployment load-bearing lines must be parallel to each other.
On every Kiva II, check that the logo is on the same side as the safety mechanism (identiable by the eyelet and
the handle shape).
Pickup point for pullback deployment
Use hole 13 on KIBU II.
Use hole 14 on KIBU-SB for Kiva II.
Use hole 13 on KIBU-SB for SB15m.
Maximum negative site angle with SB15m
The negative site angle is limited by the lifting element.
The element must not come in contact with KIBU-SB