Rigging procedures
Ceiling-mounting
Mounting a Kara IIi array with KARAIIi-TILTBRACKET
Type of deployment
ceiling-mounted
Rigging accessories
KARAIIi-TILTBRACKET
Kara IIi rigging plates
Screws and fasteners
M6×18 Torx rigging screws (provided)
4 × M10 screws and anchors
Tools
torque screwdriver
T30 Torx bit
Min. number of operators
3
Rigging plates
x2
x2
x2
KARAIIi-TILTBRACKET
Fastening brackets
with angles for Kara IIi
KARAIIi-LINK
Rigging plates
for Kara IIi
KARAIIi-ENDLINK
End rigging
plates for Kara IIi
Fasteners for ceiling-mounting
Select screw length and anchors applicable to the ceiling properties.
Model the array in Soundvision and check the loads on rigging in the
Mechanics view
.
Mounting KARAIIi-TILTBRACKET to the ceiling
When mounting Kara IIi to the ceiling with KARAIIi-TILTBRACKET, Kara IIi must be turned
upside-down
(logo on
the left-hand side).
Otherwise, it is not possible to mount additional Kara IIi under the rst one, and the site angle is not accurate.
For aesthetic purposes, the front grills can be removed and exchanged when the enclosures are assembled. Refer
to
(p.92).
Kara IIi owner's manual (EN) version 2.0
67
Содержание Kara IIi
Страница 1: ...Kara IIi owner s manual EN ...
Страница 106: ...Corrective maintenance CONNECTOR PLATE HF DIAPHRAGM G03520 HF DRIVER G03521 106 Kara IIi owner s manual EN version 2 0 ...
Страница 130: ...Speci cations SB28 dimensions 700 mm 27 6 in 1300 mm 51 2 in 550 mm 21 7 in 130 Kara IIi owner s manual EN version 2 0 ...
Страница 142: ...L Acoustics 13 rue Levacher Cintrat 91460 Marcoussis France 33 1 69 63 69 63 info l acoustics com www l acoustics com ...