Targa Systems Division
S4 Ethernet NAS DTS Installation Guide
32003272-1 Rev 5
4.4 DTU Configuration Page
Displays Targa DTU identification
data and provides access to the
DTU features configuration
parameters.
DTU Identification:
Model#
:
Targa DTU Model
#
Serial#
:
DTU serial
number
Firmware:
DTU firmware
version and part
number
DTU Features
Erase Input / Erase Algorithm:
The Targa DTU supports a
remote sourced Erase input
signal used to activate a user
specified DTD Security Erase
algorithm. Refer to Appendix B for details on the supported Sanitize / Secure
Erase algorithms.
If the Erase input is disabled, the Erase Algorithm entry is not applicable.
Factory default is disabled.
Erase Input Signal: (Secure_Erase- refer to 2.6.3 & 3.7)
Active low input signal. Signal must transition from Off state (logic high) to On
state (logic low) and be logic low for a minimum of 300msec for DTU to
activate erase. If the signal is detected as logic low at power up or at door
closure the signal is disqualified until it returns to the logic high state (for a
minimum 300msec). If the Erase Input feature is disabled the signal is not
monitored.
Refer to the FTP Site command “dtdsanitize” for details on the ethernet
commanded DTD Secure Erase.
Enable Temp Alerts:
Enabled
Disabled
The DTU is equipped with an on-board temperature sensor that can be used
to monitor the internal temperature. The temperature monitoring process can
also, when enabled, issue an alert at a user specified temperature. Refer to
the FTP Site command section for details on how to read unit temperature
and detect a temperature alert.
Factory default is disabled.
Temperature Alert at:
Default: 90ºC
Input range: 80ºC to 100ºC
Temperature Alert value is used only when Temp Alert is enabled
15