Targa Systems Division
S4 Ethernet NAS DTS Installation Guide
32003272-1 Rev 5
4.3 DTU-INFO Page
Displays Basic DTU information:
Model#
:
Targa DTU Model #
Serial#
:
DTU serial number YYMMxxxxxx
YYMM is the DTU date of
manufacture
xxxxxx is the DTU MAC
address
Firmware:
DTU firmware version and part
number
Config Mode:
Must be enabled to update
unit configuration data.
See section 2.6.3
System Time
: Current time within the DTU
At power up defaults to 00:00:00 January 1, 1970 GMT
DTU time can be set via 2 mechanisms
- FTP Site Command “SETTIME”
- rdate server - time is requested at power-on (refer to the DTU
Network configuration page for details)
Uptime:
Length of time that the DTU has been operational.
Uptime can be used to determine if the DTU has experienced a
power failure recovery since it was last accessed (ie: if your current
directory has changed back to the default mount point due to
system reboot)
Load Avg
:
Measure of average DTU CPU utilization use as a % over time for
the past: 1 min, 5 min, 15 min
Load Avg can be used as a reference, during test and integration to
determine if there are sufficient resources available to handle more
client sessions or file transfers. Note: 1.0 = 100% and loads > 1.0
are normal.
Power State
: Status of input power:
Good
- input power within range
Power-fail
- input power is < 17Vdc and DTU is operating in
power-fail protection mode.
Refer to Section 3.6 for more details.
DTD State
Status of DTU access door as well as DTD #1 [and DTD #2 ]
Door Open
Door Closed, DTD Not Present
Door Closed, DTD Present
Door Closed, DTD Present, Write Protected
14