Installation
STE User’s Manual
2-4
Rel. 2.6
2-2.1.2 Red Expansion Port
The
RED EXPANSION PORT
is a PCMCIA expansion slot for the addition of future applications.
2-2.1.3 Red Serial Data Port 1
The
RED SERIAL DATA PORT 1
interface can be configured for either EIA-530A or EIA-232 using the
STE HMI menu. At this port, the STE functions as a DCE (Data Communication Equipment) interface.
2-2.1.4 Red Serial Data Port 2
The
RED SERIAL DATA PORT 2
is installed in the Data STE, STE-R, and STE-RT units. It is reserved
for future capabilities but may also be used to provide a hard reset for the STE.
2-2.1.5 Power
Port
The
POWER PORT
is a DB9 connector used to connect to the STE Power Supply.
2-2.1.6 ISDN
Port
The
ISDN PORT
is an S/T interface (RJ-45 connector) used to connect to the ISDN service.
2-2.1.7 ISDN Selector Switches
The
ISDN TERMINATION SWITCHES
are used to set the ISDN characteristics. For point-to-point ISDN
Mode (the only mode currently supported), they are set to the “ON” (up) position.
2-2.2
Ports Located in the Wedges
2-2.2.1 PSTN
Port
The
PSTN PORT
is an RJ-11 connector located on the rear of the conventional PSTN Wedge and the
International PSTN Wedge.
2-2.2.2 TRI-TAC
Port
Located in the rear of the Tactical STE and STE-RT, the
TRI-TAC PORT
is either a Molex connector (on
older versions of the STE) or four spring-loaded terminal posts (on the newer STE versions). Use this
port to connect your STE to the TRI-TAC service.
2-2.2.3 Black Digital Interface (EIA-530A/EIA-232) Port
The Black Digital Interface port or the
BDI PORT
, is a 25-pin D-connector located in the rear of both the
Tactical STE and the STE-RT. You will use this port to connect to the BDI service. You can configure the
port as either an EIA-530A or EIA-232 via selections in the STE HMI menu.
2-3. GENERAL
PRE-INSTALLATION
REQUIREMENTS
Before you install your STE, you should determine the following:
•
Identify the type of STE you wish to install (CEU, Office STE, STE-R, STE-RI, STE-RT, Digital
STE or Tactical STE).
You can connect an Office STE or STE-R to either an ISDN or PSTN.
You can connect a Tactical STE or a STE-RT to ISDN, PSTN, TRI-TAC (TRI Service TACtical
network), or a serial EIA-530A/EIA-232 network (referred to as a Black Digital Interface (BDI)).
A CEU or STE-RI can only be connected to ISDN.
Ensure you have a complete STE, with all components of the STE type you are installing
(Paragraph
•
The telephone service (PSTN, ISDN, TRI-TAC, BDI) to which the STE will be connected.
For some applications to be enabled, the STE must be connected to an ISDN network.
Ensure your telephone line functions properly.
•
Identify where you will locate the STE within the facility
•
Ensure your STE has access to a power source. See Paragraph
•
Verify the proper connections for each type service are available at the desired location.
Your facilities manager can tell you what services are presently available at your location and what
Содержание Office STE
Страница 2: ...Copyright 2006 L 3 Communications Corporation ...
Страница 26: ...List of Tables STE User s Manual xiv Rel 2 6 This page intentionally left blank ...
Страница 32: ...Introduction STE User s Manual 1 6 Rel 2 6 This page intentionally left blank ...
Страница 92: ...Controls Indicators and Interfaces STE User s Manual 3 12 Rev 2 6 This page intentionally left blank ...
Страница 132: ......
Страница 181: ...STE User s Manual Crypto Card Management Rel 2 6 6 25 ...
Страница 182: ......
Страница 210: ...Calls STE User s Manual 7 28 Rel 2 6 This page intentionally left blank ...
Страница 234: ...Remote Control Operations STE User s Manual 8 24 Rel 2 6 This page intentionally left blank ...
Страница 258: ...8510 Capabilities STE User s Manual 9 24 Rel 2 6 This page intentionally left blank ...
Страница 284: ...User Maintenance STE User s Manual 11 6 Rel 2 6 This page intentionally left blank ...
Страница 288: ...Notes STE User s Manual 12 4 Rel 2 6 12 4 CE DECLARATION OF CONFORMITY ...
Страница 306: ...Index STE User s Manual Index 18 Rel 2 6 This page intentionally left blank ...
Страница 308: ...Rel 2 6 FP 2 FO 2 User Tree ...
Страница 311: ......