background image

Содержание ZV1-SC

Страница 1: ...ION MANUAL MODEL ZVI SC I AZVI SC SINGLE DECK PRODUCE SELF CONTAINED THIS REFRIGERATOR CONFORMS TO THE COMMERCIAL REFRIGERATOR MANUFACTURERS ASSOCIATION HEALTH AND SANITATION STANDARD DIVISION OF KYSOR INDUSTRIAL CORPORATION 1600 INDUSTRIAL BLVD CONYERS GEORGIA 30207 404 483 5600 5201 TRANSPORT BLVD COLUMBUS GEORGIA 31907 ...

Страница 2: ...operated according to the instructions contained in this manual to insure proper performance They are designed for display of products in an air conditioned store where temperature and humidity are maintained at a maximum of 75 degree F dry bulb 55 relative humidity MODELS DESCRIPTION ZVl SC Single Deck Self Contained Produce Case on 4 Swivel Casters 48 3 4 High Without Canopy A ZVl SC Same as Abo...

Страница 3: ...ION This refrigerator leveled For proper back of the case and must be located on a firmly based floor operation airflow 6 minimum required wall and between CLEANING To insure minimum maintenance cost the case should be thoroughly emptied and cleaned every three 3 months The exterior should be cleaned weekly A mild soap and water solution is recommended for painted surfaces of the case Do not use c...

Страница 4: ...ary to adjust superheat place a thermocouple under the expansion valve bulb Read the suction line pressure as near coil as possible If at the condensing unit estimate suction line loss at 2 PSIG Convert coil suction pressure to temperature The difference between coil temperature and the thermocouple temperature is superheat Use average superheat when expansion valve is hunting Do not set superheat...

Страница 5: ...8 9 amp 20 amP CHART 2 RECOMMENDED CONTROL SETTING REFRIGERANT TYPE CHARGE Low PRESSURE LP HIGH PRESSURE HP DEFROST PERIODS DEFROST TIME SETTING THERMOSTAT QUANTITY THERMOSTAT S SETTING ZVl SC A ZVl SC R 22 2 75 lbs CUT OUT CUT IN CUT OUT CUT IN 25 psig 45 psig 370 psig 280 psig 450 psig 6 24 hrs 30 min 1 ea 2 ea 20 F 20F 3OF Defrost frequency is specified at design conditions Higher temperature o...

Страница 6: ...034 05A20 167 08AlO 086 08All 077 08Al2 138 09AlO 055 09AlO 069 09BlO 059 09BlO 064 10510 024 10510 045 10514 172 lOK12 062 lOMlO 193 13A15 012 Casters Swivel Plt Brk Model 17BlO 014 Heater Condensate Evapoway Condenser Coil Assy Panel Upper Front Panel Lower Front Perf Panel Back Upper Panel Back Lower Perf Kickplate Front Rear Brt Kickplate End Hinge Assy Brt 28H12 029 32A16 145 5lA12 224 5lA12 ...

Страница 7: ...rt No ZVl SC A W SC 82A17 03tf 1 Box Electric Control Assy 82A17 039 1 Coil Assy 86C14 166 1 1 Condensing Unit Assy 88AlO 017 1 Condensing Unit Amy EEAlO 018 1 Pm Evaporator Assy 89810 029 1 1 Plenum Fan Assy 96Cl9 277 1 1 ...

Страница 8: ...HER OBLIGATIONS OR LIABILITIES OF KYSORJWARREN THIS WARRANTY SHALLNOTAPPLY 1 2 3 4 5 6 7 To the condensingunit usedwith refrigerated equipmentunlesssamewassoldandshippedby KYSOIUWARREN Whenthis equipmentor any part thereofisdamaged by fire flood actof God or whentheoriginal modelandserial numberpiate has beenaltered defaced or removed Whenthis equipmentor any part thereofis subjectto accident alte...

Отзывы: