Kyoto Kagaku NW8 Скачать руководство пользователя страница 1

Contents

Introduction 

Set includes/DOs and DON’Ts

Before you start

Training

After Training

P.16

P.17

P.18-P.19
P.20-P.21

P.22-P.23

P.24-P.28

Trouble shooting

P.29

Tube Feeding Simulator

Preparation (on the bed)

Preparation (on the table)

set includes

Training procedure 

NW8

 (NG, OG and PEG)

Instruction Manual

Don’ t mark on the model and other components 

with pen or leave printed materials contacted on 

their surface. 

Ink marks on the models will be irremovable.

Caution

Содержание NW8

Страница 1: ... P 24 P 28 Trouble shooting P 29 Tube Feeding Simulator Preparation on the bed Preparation on the table set includes Training procedure NW8 NG OG and PEG Instruction Manual Don t mark on the model and other components with pen or leave printed materials contacted on their surface Ink marks on the models will be irremovable Caution ...

Страница 2: ... with the enclosed instructions is strictly discouraged The manufacturer cannot be held responsible for any accident or damage resulting from such use Should you have any questions on this simulator please feel free to contact our distributor in your area or KYOTOKAGAKU at any time Our contact address is on the back cover of this manual Handle the manikin and the components with care Talcum powder...

Страница 3: ...elow Before You Start Set includes a f g b c d e Tube Feeding routes model 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece Male Torso Support Base Drain Hose Funnel Plastic cup Tube Feeding chest sheet Plug for drain port Silicone based lubricant Guide book g h 1 piece h 1 piece ...

Страница 4: ...e of the frame and the table 3 Connect the drain hose to stomach parts steadily In case training requires to keep the level of water in the stomach and does not require feeding liquid formula to the simulator such as use of a bumper type PEG tube or training of confirmation of NG tube placement close the drain port with the included plug instead of connecting the drain tube Insert the plug firmly ...

Страница 5: ...aining on the bed 3 Put the end of the drain hose into the bucket 4 Fill the water in the stomach Insert the funnel into PEG hole and fill about 300cc water Attach the skin on the model 30 2 Set the torso model on the bed reclined 30 degree ...

Страница 6: ...g e g tissue box between the left edge of the frame and the table 3 Connect the drain hose to stomach parts steadily In case training requires to keep the level of water in the stomach and does not require feeding liquid formula to the simulator such as use of a bumper type PEG tube or training of confirmation of NG tube placement close the drain port with the included plug instead of connecting t...

Страница 7: ... into PEG hole and fill about 300cc water 2 Attach the skin on the model 5 Fill the water in the stomach When using a bumper type PEG tube and seeking to confirm its placement use the plug for the drain port of the stomach and fill the stomach with water till the bumper is submerged water bumper stomach cap bumper type PEG tube ...

Страница 8: ...lator Larger catheters will result in unsuccessful insertion In this simulator catheter will reach the stomach after 50cm insertion Caution Caution 2 Training the fixation of the catheter with tape Do not leave the tape on the skin of the simulator If the tape is left adhered for a prolonged period of time the skin surface will remain sticky from adhesive of the tape If you fix the catheter with t...

Страница 9: ... Hold the torso with both hands and tip it to drain the content 3 Remove the skin and pull out the PEG catheter 4 Refill the stomach with 300cc water for the next training 2 PEG procedure 1 Fixing PEG catheter Fix the balloon catheter for PEG with about 5ml air Do not use water or any liquid 5 ml is the guide value for the recommended balloon catheter for PEG NIPRO 20Fr PEG button catheter For oth...

Страница 10: ...ning on the bed Be careful not to slip or drop the torso when lifting and tilting it Use its two handling holes After training that uses the plug for drain port Lift the side of drain port and pull and remove the plug upwards while taking care not to spill water Then tilt the torso above a container to discard the water from the stomach Be careful that the discarded water won t flow out of the cac...

Страница 11: ...inside of the catheter Then pull out the NG tube from the torso PEG catheter Inject the mildly hot water to the PEG catheter with a syringe to clean the inside of the tube and catheter Then pull out the PEG catheter or tube from the torso In case of a fixed PEG catheter insert the syringe to the catheter valve and remove the air Then pull out the PEG catheter carefully from the torso Caution ...

Страница 12: ... stomach part is easier on the table than on the bed Training on the table After the catheters are removed clean the stomach with mildly hot water Repeat cleaning the stomach until the water doesn t include nutrient solution anymore Then remove the hose from the stomach part Training on the bed ...

Страница 13: ...rvical part from under the model and pull the esophagus from cervical part Wash and dry well the stomach and all other parts Clean the stomach part with sodium hypochlorite if it is necessary Follow the instruction of the antiseptic for how to use it Cleaning 3 Remove the esophagus from the stomach model torso esophagus stomach PEG part ...

Страница 14: ...g Setting the parts 1 Attach the stomach with esophagus as shown in the pictures below 2 Insert the esophagus into the cervical part steadily Then attach the PEG part to the stomach by twisting it clockwise 3 Put the skin on the model ...

Страница 15: ...ew ones Q Cannot insert the catheter A1 Catheter size may be larger than the recommend size Use 14Fr catheter for NG and Oral 20Fr for PEG A2 Lubricant may not be sprayed on catheter and nasal passage Spray the lubricant Silicone based lubricant to catheter and nasal passage Q Cannot hear the bubble sound in the stomach A1 There may be no water in the stomach Fill 300cc water in the stomach A2 Bal...

Страница 16: ...e No part of this instruction manual may be reproduced or transmitted in any form without permission from the manufacturer Please contact manufacturer for extra copies of this manual which may contain important updates and revisions Please contact manufacturer with any discrepancies in this manual or product feedback Your cooperation is greatly appreciated For inquiries and service please contact ...

Отзывы: