This instrument satisfies the marking requirement defined 

in the WEEE Directive. This symbol indicates separate 

collection for electrical and electronic equipment.
This marking means they shall be sorted out and collected 

as ordained in DIRECTIVE.

This directive is valid only in the EU. When you remove 

batteries from this product and dispose them, discard them 

in accordance with domestic law concerning disposal. Take 

a right action on waste batteries, because the collection 

system in the EU on waste batteries are regulated.

#

 

WARNING

Measurement Category(CAT)

 The restrictions on the maximum voltage level for which 

the this product can be used, depend on the measurement 

categories specified by the safety standards.

 Do not apply any input level higher than maximum allowable 

input.

AC/DC 600V

CAT II

    

AC/DC300V  CAT III

CAT II

Appliances, portable equipment, ect. For measurements 

performed on circuits directly connected to the low 

voltage installation.

CAT III D i s t r i b u t i o n  b o a rd ,  c i rc u i t  b re a k e r,  e c t .  F o r 

measurements performed in the building installation.

#

 

DANGER

 Never make measurement on circuits with a maximum voltage 

difference of 600V or greater between conductors (300V or 

greater between a conductor and ground).

 Do not attempt to make measurement in the presence of 

flammable gasses.

 Otherwise, the use of the instrument may cause sparking, 

which leads to an explosion.

 Never attempt to use the instrument if its surface or your hand 

is wet.

 Do not exceed the maximum allowable input of measuring 

ranges.

 Never open the battery compartment cover while making 

measurement.

 Never try to make measurement if any abnormal conditions, 

such as broken Clamp Sensor or case is noted.

 The instrument is to be used only in its intended applications or 

conditions.

 Otherwise, safety functions equipped with the instrument 

doesn t work, and instrument damage or serious personal 

injury may be caused.

1

SAFETY WARNINGS

This instrument has been designed and tested according to 

IEC Publication 61010: Safety Requirements for Electronic 

Measuring Apparatus. This instruction manual contains warnings 

and safety rules which must be observed by the user to ensure 

safe operation of the instrument and to retain it in safe condition. 

Therefore, read through these operating instructions before 

starting using the instrument.

#

 

WARNING

 Read through and understand instructions contained in this 

manual before starting using the instrument.

 Save and keep the manual handy to enable quick reference 

whenever necessary.

 Be sure to use the instrument only in its intended applications 

and to follow measurement procedures described in the 

manual.

 Be sure to understand and follow all safety instructions 

contained in the manual.

Failure to follow the above instructions may cause injury, damage 

to the instrument and/or damage to equipment under test.

The symbol 

#

 indicated on the instrument means that the user 

must refer to related parts of the manual for safe operation of 

the instrument. Be sure to carefully read the instructions following 

each 

#

 symbol in this manual.

#

 

DANGER

is reserved for conditions and actions that are 

likely to cause serious or fatal injury.

#

 

WARNING

is reserved for conditions and actions that can 

cause serious or fatal injury.

#

 

CAUTION

is reserved for conditions and actions that can 

cause minor injury or instrument damage.

Following symbols are used on the instrument and in the 

instruction manual. Attention should be paid to each symbol to 

ensure your safety.

#

Refer to the instructions in the manual.

This symbol is marked where the user must refer to the 

instruction manual so as not to cause personal injury or 

instrument damage.

Indicates an instrument with double or reinforced insulation.
Indicates that this instrument can clamp on bare conductors 

when measuring a voltage corresponding to the applicable 

Measurement category, which is marked next to this symbol.

Indicates AC (Alternating Current)

Indicates DC (Direct Current).

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание KEW MATE 2012RA

Страница 1: ...DIGITAL MULTIMETER WITH AC DC CLAMP SENSOR KEW MATE 2012RA www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...his instrument has been designed and tested according to IEC Publication 61010 Safety Requirements for Electronic Measuring Apparatus This instruction manual contains warnings and safety rules which m...

Страница 3: ...omes standard with the instrument Clamp sensor for ease of use in crowded cable areas and other tight places Permits current measurement with an open current clamp sensor that does not require opening...

Страница 4: ...Input Voltage 600V Range Display range Allowable input Accuracy 600mV 0 0 603 9mV 0 0m 600 0V 1 0 rdg 3dgt 6V 0 560 6 039V 60V 5 60 60 39V 600V 56 0 603 9V Input Impedance approx 10M Resistance Auto...

Страница 5: ...g System modulation Display Liquid crystal display Maximum Reading 6039 Except Hz 9999 CAP 4039 Diode 1999 Bar graph with maximum points of 30 Display approx 3 times per second Indication renewal Loca...

Страница 6: ...the batteries according to section 8 Battery Replacement NOTE When the instrument is left powered on the auto power save function automatically shut the power off The display blanks even if the Functi...

Страница 7: ...LCD 2 Adjust one of the conductors to the center of the clamp sensor s arrow When the position of the conductor is not at the center of the arrow the error occurs Measured value is shown on the displa...

Страница 8: ...urement DANGER In order to avoid possible shock hazard never make measurement on circuits with a maximum voltage difference of 600V or greater between conductors 300V or greater between a conductor an...

Страница 9: ...Turn the function switch to the OFF and then to any position 7 2 Data Hold Function This is a function to freeze a measured value on the display Press the Button once to hold the current reading In t...

Отзывы: