13.9
KEW6305
<
MODEL8125
>
<
MODEL8124
>
Rated current
AC 500 Arms (707 Apeak)
AC 1000 Arms (1414 Apeak)
Output voltage
AC 0 – 500 mV
(AC 500 mV/ 500 A)
:
AC 1 mV/A
AC 0 – 500 mV
(AC 500 mV/ 1000 A)
:
0.5 mV/A
Measuring range
AC 0 – 500 Arms
AC 0 – 1000 Arms
Accuracy
(sine input)
±0.5%rdg±0.1 mV (50/ 60 Hz)
±1.0%rdg±0.2 mV (40 Hz – 1 kHz)
±0.5%rdg±0.2 mV (50/ 60 Hz)
±1.5%rdg±0.4 mV (40 Hz – 1 kHz)
Phase
characteristics
within ±1.0°
(5 – 500 A/ 45 – 65 Hz)
within ±1.0°
(10 – 1000 A/ 45 – 65 Hz)
Temp. & humidity
range (guaranteed
accuracy)
23±5°C, relative humidity 85% or less (no condensation)
Operating temp.
range
0 - 50°C, relative humidity 85% or less (no condensation)
Storage temp.
range
-20 to 60°C, relative humidity 85% or less (no condensation)
Allowable input
AC 500 Arms (50/ 60Hz)
AC 1000 Arms (50/ 60 Hz)
Output impedance
Approx. 2
Ω
Approx.
1
Ω
Location for use
indoor use, altitude 2000m or less
Applicable standard
IEC 61010-1, IEC 61010-2-032
Measurement CAT III 600 V, Pollution degree 2
IEC61326
Withstand voltage
AC 5350 V/ 5 sec
between Jaws – enclosure, enclosure – output terminal,
Jaws – output terminal
Insulation
resistance
50 M
Ω
or more/ 1000 V
between Jaws – enclosure, enclosure – output terminal, Jaws –
output terminal
Max conductor size
Φ
40mm
Φ
68mm
Dimension
128(L)×81(W)×36(D)mm 186(L)×129(W)×53(D)mm
Cable length
Approx. 3m
Output terminal
MINI DIN 6PIN
Weight
Approx. 260g
Approx. 510g
Accessory
Instruction manual, Cable marker
Option 7146
(
Φ
4 Banana plug), 7185 (Extension lead)