2FT-3.0
1-6-25
(2-2) Fitting the scanner wires
Caution:
When fitting the wires, be sure to use those specified below.
Machine front: P/N 2C91236 (gray)
Machine rear: P/N 2C91235 (black)
Fitting requires the following tools:
Two frame securing tools (P/N 302C968310)
Two scanner wire stoppers (P/N 3596811)
Procedure
1. Remove the screw and then scanner wire
drum gear at the machine rear side.
Figure 1-6-45
2. Remove the stop ring and bushing from the
front of the scanner wire drum shaft.
3. Remove the scanner wire drum shaft from
the scanner unit.
Figure 1-6-46
Scanner wire
drum gear
Scanner wire drum shaft
Bushing
Stop ring
Содержание KM-2550
Страница 1: ...SERVICE MANUAL Published in June 2005 842FT112 Version 3 0 KM 2550...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 123: ...2FT 1 1 4 56 This page is intentionally left blank...
Страница 249: ...2FT 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC...
Страница 267: ...2FT 2 3 20 Figure 2 3 10 Operation unit PCB silk screen diagram...
Страница 282: ......