2PR
1-5-41
(5) Detaching and refitting the high voltage PWB 2
Procedure
1. Remove the duplex unit B (See page 1-5-
2. Release four hooks and then remove the
DU feed guide.
Figure 1-5-57
3. Remove three screws.
4. Release three hooks and then remove the
high voltage PWB 2.
5. Remove the connector.
6. Check or replace the high voltage PWB 2
and refit all the removed parts.
Figure 1-5-58
Hook
Hook
DU feed guide
Screw
Screw
Screw
Hook
Hook
Hook
Connector
High vlotage PWB 2