2-30
The main unit setup procedure > Installation
[CONFIDENTIAL]
(8) Head treatment unit (Remove the fixing screws)
1
Push the treatment unit [A] into the main unit.
2
Please make sure to check the position of the screw with the tag [B] located at
bottom side of the treatment unit [A].
3
Remove the screws with the stubby driver (Total length 95mm or less) to release the
treatment unit [A]. (Screw x5)
IMPORTANT
If forgetting to remove the screw on the bottom, the wipe unit can not be moved, resulting in an error (C2000).
C2000: Treatment lift motor error.
(After removing the fixing screw, it will recover by turning on the power switch.)
[A]
[B]
[A]