2-26
The main unit setup procedure > Installation
[CONFIDENTIAL]
(5) Installation of the cleaning tank
1
Open the cleaning liquid tank cover [B] by rotating lock lever [A] in the direction of
the arrow.
2
Insert the cleaning liquid tank [A] in the direction of the arrow and stop at gap.
3
Remove the tape [B] on side and the vent spacer [C].
IMPORTANT
The liquid may overflow by holding the tank on the side as handing it.
Wear powder free rubber gloves in handling and pay attention to overflow or leaking. (If the liquid get your bare
hands, rinse it immediately with water.)
Missing the vent spacer may get C7360 since supplying cleaning liquid to sub tank stagnates. In set up, the C
call may happen after the main unit works so please be careful about the spacer. (Perform U743 to release the
C call.)
[A]
[B]
[A]
[C]
[B]