6-52
Machine transportation after setup > Procedure for the main unit transportation (Truck transportation)
[CONFIDENTIAL]
71
Attach the left upper cover [A] in the direction of the arrow. (Screw x11)
72
Attach the rear left upper cover [A] and turn the power switch on. (Screw x6)
Wait more than 5 seconds between the power off and on.
73
Enter maintenance mode.
74
Select [Cleaning] in U744 Head Cleaning and select [Normal] for each color then
press [Execute]/[Start] to run purge.
IMPORTANT
The machine can be operated by the ink temperature of over 26 °C.
Once it is executed, it is not possible to cancel the operation.
In case of displayed temperature is below 26 °C, select the priority mode to "Printing" in U735 <Ink temperature
control setting>..