2-2
The main unit setup procedure >
[CONFIDENTIAL]
Loading paper
Collect the head cap
•
Remove the protective caps for shipping.
Head treatment unit
(Remove the fixing screws)
•
Push the treatment unit inside the main unit and remove the screws for the head treatment unit.
Image conveying unit
(Re-install to the original position)
•
Re-install the image conveying unit.
Ink initial supply (Set up flow)
Initial ink supply to the print head
•
Syringe of the Ink and the cleaning liquid, the air vent and fill up for the circulation pipe and the
filter.
•
Perform set up mode
•
Replace the preserving liquid in the print head unit to the ink and the cleaning liquid by purging and
filling up
•
Remove nozzle clogging (purge): U744
Adjustment
Head position adjustment
•
Check head position adjustment: U468
Head top timing adjustment: U469
Head overlap adjustment: U469
•
Color registration adjustment: U469
Head skew adjustment: U469
•
White line correction setting: U744
Print position adjustment
•
Paper lead edge timing: U034
•
CIS print position: U755
Other maintenance mode
Содержание AK-9110