10..Brake System
XCITING S 400
ABS Troubleshooting Outline
The ABS indicator light lights up to alert the rider when an abnormality is detected
by the system. The service codes are stored in the ABS unit memory. The codes
will not be erased unless manually cleared. After the fault has been corrected
erase the service codes.
Even when the ABS is operating normally, the ABS indicator light may light up
under the conditions listed below. Turn the ignition switch OFF to stop the
indicator light. If the scooter runs without erasing the service codes, the light may
light up again.
□ After continuous riding on a rough road.
□ When the ABS has been subjected to strong electrical interference.
□ When tire pressure is abnormal. Adjust tire pressure.
□ When a tire different in size from the standard size is being used. Replace with
standard size.
□ When the wheel is deformed. Replace the wheel.
Much of the ABS troubleshooting work consists of confirming continuity of the
wiring. The ABS parts are assembled and adjusted by the manufacturer, so there
is no need to disassemble or repair them. Replace the ABS hydraulic unit if
needed.
The basic troubleshooting procedures are listed below.
□ Carry out pre-diagnosis inspections as a preliminary inspection.
□ Check wiring and connections from the ABS hydraulic unit connector to the
suspected ABS part, using the diagnosis tool.
Special tool - Diagnosis tester: 3620A-LEB2-E00
□ Visually inspect the wiring for signs of burning or fraying. If any wiring is poor,
replace the damaged wiring.
□ Pull each connector apart and inspect it for corrosion, dirt and damage. If the
connector is corroded or dirty, clean it carefully. If it is damaged, replace it.
□ Check the wiring for continuity.
10-24
Содержание ADG5
Страница 12: ...1 Quick Reference XCITING S 400 1 12 Torque Engine Specifications...
Страница 13: ...1 Quick Reference XCITING S 400 1 13 Torque Frame Specifications...
Страница 16: ...1 Quick Reference XCITING S 400 1 16 General Troubleshooting...
Страница 17: ...1 Quick Reference XCITING S 400 1 17...
Страница 18: ...1 Quick Reference XCITING S 400 1 18...
Страница 19: ...1 Quick Reference XCITING S 400 1 19...
Страница 20: ...1 Quick Reference XCITING S 400 1 20 VIN and Engine Number Location...
Страница 23: ...2 Periodic Maintenance XCITING S 400 9 3...
Страница 72: ...3 External Components XCITING S 400 Heat Shield Removal Remove bolts and remove the heat shields 3 16...
Страница 103: ...XCITING 400i 3 Engine Camshaft Inspect the camshaft sprocket for worn teeth or other signs of wear or damage 3 25...
Страница 114: ...3 Engine Valves XCITING 400i Remove the spring retainer Remove the valve springs 3 36...
Страница 143: ...3 Engine Generator XCITING 400i Remove the generator cover gasket Remove the two dowel pins 3 65...
Страница 208: ...5 Cooling System XCITING S 400 Jump a 12 volt battery to the fan connector and make sure the radiator fan operates 5 15...
Страница 243: ...6 Fuel System XCITING S 400 6 30 Removal Throttle Cables Free the throttle cables from the throttle drum...
Страница 329: ...9 Electrical Systems XCITING S 400 9 29 Check the circuit with the wire...
Страница 336: ...9 Electrical Systems XCITING S 400 9 36 Meter Instrument Remove couplers Check the wiring diagram to inspect circuit...
Страница 340: ...10 Brake System XCITING S 400 Diagram 10 3...
Страница 362: ...10 Brake System XCITING S 400 Pre diagnosis Inspection Chart 1 10 25...
Страница 363: ...10 Brake System XCITING S 400 Pre diagnosis Inspection Chart 2 10 26...