KYLAND SICOM3000S Скачать руководство пользователя страница 19

 

Connection

 

 

 

The switch provides a grounding screw on the top panel for chassis grounding. After 

crimping one end of the grounding cable to a cold pressed terminal, fix the grounding screw 

and connect the other end to the earth firmly.   

 

Note: 

 

Cross-sectional area of the chassis grounding cable>2.5 mm

2

; grounding resistance<5Ω.

   

4.6 Power Terminal Block 

The power terminal is located on the cover plate of the  device, and the power cord is 

connected to the terminal block to supply power to the device. This device supports redundant 

power input and adopts 5 core 5.08 mm spacing plug-in terminal block. when any one of the 

power supply failure, the device can run normally without interruption, improve the reliability 

of network operation.   

 

说明:

 

  Power cord cross-sectional area should be above 0.75mm

2

 (max cross-sectional is 2.5mm

2

)

grounding resistance<5

 

  Copper conductor must be used for field wiring and the temperature should 

meet 75

  5-Pin 5.08mm-Spacing Plug-in Terminal Block   

 

 

Figure 13 5-Pin 5.08mm-Spacing Plug-in Terminal Block (socket) 

Table 6    Pin Definitions of 5-Pin 5.08mm-Spacing Plug-in Terminal Block 

No. 

Signal 

DC Definition 

AC Definition 

+/L 

PWR1

PWR1

-/N 

PWR1

PWR1

Содержание SICOM3000S

Страница 1: ...SICOM3000S Industrial Ethernet Switch Hardware Installation Manual Publication Date May 2021 Version V1 1 No 112020193...

Страница 2: ...ated as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users All rights reserved No part of this documentation may be excerpted reprod...

Страница 3: ...ls on the device or cables Ensure adequate heat dissipation and tidy cable layout without knots Wear antistatic gloves or take other protective measures when operating the device Avoid any exposed met...

Страница 4: ...bstitute Do not purchase parts from other channels Dispose of the device in accordance with relevant national provisions preventing environmental pollution In the following cases please immediately sh...

Страница 5: ...000Base T X ethernet port 12 4 2 POE Function 13 4 3 1000Base X 10 100 1000Base T X SFP interface 14 4 3 1 SFP optical module 15 4 4 Console Port 16 4 4 1 RJ45 Console Port 16 4 5 Grounding 17 4 6 Pow...

Страница 6: ...8 Basic Features and Specifications 29...

Страница 7: ...EE802 3af The switch can provide a maximum of 240W L16 power The specific configuration is as follows Table 1 SICOM3000S Configuration Table Model number SICOM3000S 4GX8GP L16 L16 SICOM3000S 4GX8P L16...

Страница 8: ...LED 2 PWR 2 LED 3 Run LED 4 Ring status LED 5 Reset button 6 Alarm LED 7 1000M SFP interface 8 1000M SFP interface speed LED yellow 9 1000M SFP interface link status LED green 10 1000M SFP interface...

Страница 9: ...Structure and Interface 15 output signal LED 16 input signal LED 17 POE output LED 18 output signal interface 19 output GND 20 input signal interface 21 input GND 2 2 Top Panel Figure 2 Top panel...

Страница 10: ...are only for reference 3 2 Mounting Modes and Steps The switch supports DIN rail mounting Before installation make sure that the following requirements are met 1 Environment temperature 40 to 85 ambie...

Страница 11: ...tch and ensure enough space and smooth heat dissipation Step 2 Clamp the top of the rail seat on the DIN rail slightly force up the bottom of the device rotate the device follow arrow 2 as below figur...

Страница 12: ...Mounting Figure 5 DIN rail dismounting...

Страница 13: ...network device with a straight through or cross over cable Pin Definition Figure 6 RJ45 PIN number Table 2 10 100Base T X Ethernet Port PIN Definition PIN MDI X signal name MDI signal name 1 Receive...

Страница 14: ...Base T X ethernet interface as PSE Power Sourcing Equipment 10 100Base T X and 10 100 1000Base T X ethernet port support IEEE802 3at compatible IEEE802 3af each POE port supplies up 30W power L16 L16...

Страница 15: ...e Data TRD1 V 7 Transmit Receive Data TRD2 Transmit Receive Data TRD3 8 Transmit Receive Data TRD2 Transmit Receive Data TRD3 Note and indicate level polarities 4 3 1000Base X 10 100 1000Base T X SFP...

Страница 16: ...4 3 1 SFP optical module Figure 8 SFP optical module SFP optical module interface adopts standard LC fiber connector each interface is divided into transmit port TX port and receive port RX port To e...

Страница 17: ...d RX ports In this case swap the two connectors at one end of the fibers Caution The device uses laser to transmit signals over fiber The laser meets the requirements of level 1 laser products Do not...

Страница 18: ...le Cable Table 5 Pin Definitions of DB9 Port 9 Pin Serial Port and RJ45 Port Console Port DB9 Port 9 Pin Serial Port RJ45 Port Console Port Pin Signal Pin Signal 2 RXD Receive Data 2 TXD Transmit Data...

Страница 19: ...he device This device supports redundant power input and adopts 5 core 5 08 mm spacing plug in terminal block when any one of the power supply failure the device can run normally without interruption...

Страница 20: ...e View the status of the power LEDs on the front panel If the LEDs are on the power is connected correctly Wiring and mounting should meet the following specifications Table 7 Wiring and Mounting Spec...

Страница 21: ...k Socket Electrical parameters of relay Maximum voltage 250VAC 220VDC Maximum current 2A Maximum power 60W Maximum insulation withstand voltage 2KV Note Pin 1 and Pin 2 is a normally open contact Pin...

Страница 22: ...nt panel which provides two low drive input signal acquisition high drive output ability the input is optocoupler isolated acquisition and the output is normally open and normally close output When de...

Страница 23: ...ess the reset button 0 5 3 seconds then release to complete the device restart Press the reset button continuously for more than 3 seconds then release to restore the default configuration and restart...

Страница 24: ...DRP mode Blinking Slave DT Ring mode B Root or Normal DRP mode OFF Non ring mode Alarm LED ON Alarm OFF No alarm 1000M SFP speed status LED Yellow ON 1000M working status 100Base X OFF No connection...

Страница 25: ...OFF 10 100M working mode or no connection 10 100 1000Base T X Ethernet port link status LED Green ON The valid network connection is established Blinking Network activity OFF The valid network connect...

Страница 26: ...t of a PC with the delivered DB9 RJ45 console cable Step 2 Open Hyper Terminal in Windows OS On the Windows desktop click Start All Programs Accessories Communications Hyper Terminal Step 3 Create a n...

Страница 27: ...ardware Device Manager Port to view the communication port Step 5 Set port parameters Bits per second 115200 Data bits 8 Parity None Stop bits 1 and Flow control None as shown in the below figure Figu...

Страница 28: ...figuration Mode 7 2 Access through Telnet Step 1 Connect the network port of the PC to the Ethernet port of the switch with a network cable Step 2 On the Windows desktop click Start and Run Enter teln...

Страница 29: ...of the browser You can log in to the Web management interface by using default user name admin and password 123 Note IE8 0 or above version is recommended For details about how to access the switch an...

Страница 30: ...2 3at Terminal Block L16 5 pin 5 08mm spacing plug in terminal block Rated Power Consumption Rated power consumption 15W no PoE Physical Housing Metal no fan IP level IP40 Mounting DIN rail mounting D...