Mounting
3 Mounting
3.1 Dimension
Figure 3 DIN-rail mounting dimension (mm)
Caution:
As part of the heat dissipation system, the switch housing becomes hot during
operation. Please do not cover the switch housing when the switch is running.
The figures in this manual are only for reference.
3.2 Mounting Modes and Steps
The switch supports DIN-rail mounting. Before installation, make sure that the following
requirements are met.
1) Environment: temperature (-40
℃
to 85
℃
), ambient relative humidity (5% to 95%,
non-condensing).
2) Power requirements: Verify that the operating voltage matches the voltage range
identified on the switch.
3) Grounding resistance: <5
。
4) Avoid direct sunlight, away from heating sources or areas with strong electromagnetic