background image

 

 

 

SICOM3028GPT Series Industrial Ethernet   

Switches Hardware Installation Manual 

 

 

 

 

 

 

 

 

Publication Data: Sep. 2016 

                                        Version: V1.3 

                                       

 

 

 

 

 

 

 

 

 

 

Содержание SICOM3028GPT Series

Страница 1: ...SICOM3028GPT Series Industrial Ethernet Switches Hardware Installation Manual Publication Data Sep 2016 Version V1 3...

Страница 2: ...s updated as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users All rights reserved No part of this documentation may be excerpted r...

Страница 3: ...ls on the device or cables Ensure adequate heat dissipation and tidy cable layout without knots Wear antistatic gloves or take other protective measures when operating the device Avoid any exposed met...

Страница 4: ...quipment emits odor smoke or abnormal noise The following information applies when operating this device in hazardous locations Suitable for use in Class I Division 2 Groups A B C and D Hazardous Loca...

Страница 5: ...Module into a Lower Slot Slot 3 Slot 5 or Slot 7 10 3 1 4 Inserting a 1U Interface Module into Slot 1 12 3 2 Dismounting 12 3 2 1 Removing a 0 5U Interface Module 12 3 2 2 Removing a 1U Interface Mod...

Страница 6: ...ower Terminal Block 26 5 8 Alarm Terminal Block 28 6 LEDs 30 7 Switch Access 33 7 1 Access through Console Port 33 7 2 Access through Telnet 35 7 3 Access through Web 36 8 Basic Features and Specifica...

Страница 7: ...d in Table 1 All these features enable the switches to well suit the Smart Grid industry The series switches support 19 inch 1U rack mounting by front rear panel They provide two console ports on the...

Страница 8: ...terface Modules 0 5U Model SM6 6 Ports Connector 0 5U Code definition Code option Ports GX GE S M T SICOM3028GPT L2GT MB SICOM3028GPT L2G MB SICOM3028GPT L3GT MB SICOM3028GPT L3G MB 4GE 4GX 2GX2GE 2GX...

Страница 9: ...ization module supports one GPS input one 5M 10M frequency input and one PPS output SM6 6 PTP BO 0 5U PTP to IRIG B clock conversion module supports two IRIG B DC outputs two IRIG B AC outputs one PPS...

Страница 10: ...B SICOM3028GPT L3G MB SM6 6 MFA 0 5U Multi functional application module supports one 1000Base X 10 100 1000Base T X Combo port Note For the product information listed in these tables we reserve the r...

Страница 11: ...1 Front Panel Table 5 Description of the Front Panel No Identifier Description 1 Alarm Alarm LED 2 Run Running LED 3 Ring Ring LED 4 Lock Synchronization Finish LED 5 PWR2 Power 2 LED 6 PWR1 Power 1 L...

Страница 12: ...nel 2 2 1 1U Interface Module SM6 6 4GX 1U 1 4 four 1000Base X 10 100 1000Base T X SFP slots SM6 6 2GX2GE 1U 1 2 two 10 100 1000Base T X Ethernet ports 3 4 two 1000Base X 10 100 1000Base T X SFP slots...

Страница 13: ...two 1000Base X 10 100 1000Base T X SFP slots SM6 6 4GE 0 5U 1 4 four 10 100 1000Base T X Ethernet ports Note Its appearance is identical with that of SM6 6 4T 0 5U You can distinguish them by labels o...

Страница 14: ...details refer to the IRIG B Clock Conversion Module Hardware Installation Manual SM6 6 4D 232 422 485 0 5U SM6 6 4D A 4RS232 422 485 0 5U For details refer to the Serial Device Server Module Hardware...

Страница 15: ...ct an applicable 0 5U interface module Insert two mounting brackets into the screw holes at both sides of the module Push the brackets in direction 1 until the brackets are firmly secured to the modul...

Страница 16: ...se remove the module and check the guide rail slot for any foreign materials or deformation If the fault cannot be rectified contact our sales or technical support personnel Step 2 Push the mounting b...

Страница 17: ...acing down If the module cannot be pushed into place do not force it because too much force may cause damage to the module In this case remove the module and check the guide rail slot for any foreign...

Страница 18: ...from an upper slot and a lower slot are the same Detailed steps are as follows Step 1 Remove the two screws securing the module to the switch Step 2 Pull out the mounting brackets Step 3 Remove the m...

Страница 19: ...Interface Module Installation 13 Figure 7 Removing a 1U Interface Module...

Страница 20: ...8 Dimensions unit mm Caution As part of the heat dissipation system the switch housing becomes hot during operation Please use caution when coming in contact and avoid covering the switch housing whe...

Страница 21: ...direct sunlight distant from heat source and areas with strong electromagnetic interference 5 Devices are to be installed in an authority certified enclosure and accessible only by the use of a tool 6...

Страница 22: ...ting position for the switch and guarantee adequate space and heat dissipation house dimensions 440mm 44mm 360mm Step 2 Move the switch in direction 1 until the screw holes for securing the mounting b...

Страница 23: ...o the rack posts Step 2 Remove the switch from the rack posts Then unscrew the mounting brackets to complete dismounting Caution Cut off the power and disconnect all cables before mounting dismounting...

Страница 24: ...I or MDI X connection automatically You can connect the port to a terminal or network device with a straight through or cross over cable Pin Definition Figure 12 RJ45 Port Table 6 Pin Definitions of 1...

Страница 25: ...FC ST SC connector and each port consists of TX transmit port and RX receive port To enable data transmission between Device A and Device B connect the TX port of Device A to the RX port of Device B a...

Страница 26: ...to a terminal or network device with a straight through or cross over cable Pin Definition Figure 15 RJ45 Port Table 7 Pin Definitions of 10 100 1000Base T X RJ45 Port Pin MDI X MDI 1 Transmit Receiv...

Страница 27: ...ot requires an SFP optical electrical module to enable data transmission The following table lists the gigabit SFP optical electrical modules optional supported by the series switches Table 8 Gigabit...

Страница 28: ...d the RX port of Device A to the TX port of Device B as shown in the following figure Figure 18 Fiber Connection of an SFP Optical Module How to Connect the SFP Optical Module Insert the SFP optical m...

Страница 29: ...evice is powered on If the defined transmission distance of an SFP module is longer than 60km do not use a short fiber 20km for connection If such a short fiber is used the module will be burned 5 4 2...

Страница 30: ...le cable to connect the USB port of a PC to the console port of the switch Then you can configure maintain and manage the switch by running Hyper Terminal in Windows OS of the PC Figure 22 Console Por...

Страница 31: ...e end of a USB console cable is Mini USB connector to be inserted into the console port of the switch and the other end is the USB connector to be inserted into the USB port of a PC Figure 24 Mini USB...

Страница 32: ...lock on the rear panel of the device You need to connect the power wires to the terminal block to provide power to the device The device supports single PWR1 and redundant PWR1 and PWR2 power supply w...

Страница 33: ...wer supply system according to the power supply requirements of the device View the status of the power LEDs on the front panel If the LEDs are on the power is connected properly Wiring and Mounting s...

Страница 34: ...ed The alarm is outputted through a 3 pin 5 08mm spacing plug in terminal block Figure 27 Alarm Terminal Block socket Electrical parameters of the relay Max Switch Voltage 250VAC 220VDC Max Switch Cur...

Страница 35: ...nal block into its socket Wiring and Mounting should meet following specifications Table 13 Wiring and Mounting Specifications Terminal Type Required Torque Wire Range AWG Terminal Block Plug 4 5 5 0...

Страница 36: ...Master DT Ring mode Root DRP mode Blinking Slave DT Ring mode B Root or Normal DRP mode Off No ring Alarm LED Alarm On An alarm occurs Off No alarm occurs Synchronization Finish LED Lock On The switc...

Страница 37: ...1000Base T X Ethernet port On 1000M working state Off 10 100M working state or no connection 10 100Base T X Ethernet port On 100M working state Off 10M working state or no connection Port connection...

Страница 38: ...and SM6 6 GPS OI FI 0 5U are inserted into slots the corresponding indicators on the front panel are off all the time When SM6 6 4D 232 422 485 0 5U SM6 6 4D A 4RS232 422 485 0 5U and SM6 6 PTP over...

Страница 39: ...ch to the 9 pin serial port of a PC with the delivered DB9 RJ45 console cable Step 2 Open Hyper Terminal in Windows OS On the computer s desktop click Start All Programs Accessories Communications Hyp...

Страница 40: ...gure 29 Selecting a Serial Port Note To confirm the communication port in use right click My Computer and select Property Click Hardware Device Manager Port to view the communication port Step 5 Set p...

Страница 41: ...ow interface vlan 1 Query the default IP address of the switch Privileged mode SWITCH show version Query the version of the switch Privileged mode SWITCH reboot Restart the switch Privileged mode SWIT...

Страница 42: ...played Then you can run the commands in Table 16 to perform operations 7 3 Access through Web Step 1 Connect the network port of a PC to the Ethernet port of the switch with a network cable Step 2 Ent...

Страница 43: ...ing plug in terminal block Rated Power Consumption Rated power consumption 40W Physical Characteristics Housing Metal fanless Protection class IP40 Installation 19 inch 1U rack mounting Dimensions W H...

Страница 44: ...Basic Features and Specifications 38 SICOM3028GPT L3G SICOM3028GPT L3F 368000h SICOM3028GPT L2GT SICOM3028GPT L2FT 359000h SICOM3028GPT L2G SICOM3028GPT L2F 360000h Warranty Warranty 5 years...

Страница 45: ...8 Website http www kyland com Email support kyland com Address Building No 2 Shixing Avenue 30 shijingshan District Beijing China For more information about KYLAND products please visit our website ht...