Kyland Technology (Shanghai) Co., Ltd PTS-DR200 Time Server
- 22 -
[Figure 3-15] Clock Setting Screen
Table 14 – Clock Setting
Items
Parameters
Description
Time Reference
UTC
TAI
Set reference time as required.
UTC: Make reference time work at UTC format;
TAI: Make reference time work at TAI format.
If PTP time needs TAI time stamp, please set this
parameter to TAI format.
Time Zone
0.00H
Set time zone offset for local time.
Unit is Hour(H);
Range is between -12H and 12H.
Default value is 0.00H.
TAI UTC Offset
37
Set time offset between TAI and UTC.
Unit is Second(s);
Range is between -32768s and 32767s.
Default value is 37s.
When system uses satellite or PTP signal as time source,
the current parameter will keep the same value with time
source; when system uses IRIG-B signal as time source, the