Chapter 3 - Operating and Connection Elements, Connection Assignments
AMA 310/UMS V21.0
3.5
Ethernet (Management- and Streaming-Interface)
Pin 1 = TXD +
Pin 2 = TXD -
Pin 3 = RXD +
Pin 4 = n. c.
Pin 5 = n. c.
Pin 6 = RXD -
Pin 7 = n. c.
Pin 8 = n. c.
Figure 3-4 Ethernet (management- and streaming-interface)
3.5.1
Management Interface
For management purposes the measuring instrument is equipped with an Ethernet interface in
standard 10Base-T with a maximum data rate of 10 MBit/s.
The RJ-45 socket used is situated on the front panel.
In the current version of the instrument this interface has no function.
3.5.2
Streaming Interface
The measuring instrument is equipped with an Ethernet interface in standard 10/100Base-T with a
maximum signaling rate of 100 MBit/s.
The RJ-45 socket used is situated on the back panel.
This interface is used to stream an MPEG transport stream to the headend equipment, this can
either be done via the ASI interface (see chapter 3.6 - ASI-IN / -OUT) or via Ethernet. A signal is
applied at the streaming interface as soon as the UMS mode is activated and the IP output has
been set as transport stream interface in the UMS settings, this will be described in subsequent
chapters of this manual.
The protocol versions UDP and RTP/UDP are supported.