Chapter 11 - DOCSIS Analyzer
79
10713 Vxx.11
11.2
Connection of the measuring receiver to the multimedia socket
For measurement with the DOCSIS analyzer, you must connect the instrument via an F-plug to
IEC-plug adapter with the F-connection of a multimedia socket on which a DOCSIS signal is
present.
11.3
Measurement of the DOCSIS downstream
For downstream, the same measurement parameters can be recorded as for a DVB-C signal
(MER, BER, constellation diagram, packet error measurement, level measurement; see chapter
6.2.2 - DIGITAL (DVB-C, DOCSIS) operating mode). You can also assess the downstream via the
spectrum analyzer (see also Chapter 15 - Spectrum analyzer)
11.4
DOCSIS analysis and measurement of the DOCSIS upstream
To obtain information about the upstream, the measuring instrument must first be receiving a valid
downstream channel.
The DOCSIS analyzer receives information about the upstream and the communication with the
CMTS.
You activate the downstream receiver of the measuring instrument via the menu item
MODULATION
->
DOCSIS
in the TV measuring range (see also chapter 6.2.2 - DOCSIS
(downstream) ).
Figure 11-3 DOCSIS measuring range
You select the modulation scheme for the DOCSIS variant in another menu.