KWC MARLINO 802 141 Скачать руководство пользователя страница 3

shut-off valves

(4)

(5)

(1)

(7)

(8)

(7)

(6)

stop post
(downward)

stop ring (3)

stop post
(downward)

cartridge stem

close

stop ring

C

H

stop post

A)

B)

rotating of the stem

(9) to the desired

max. temperature

close

max. hot temperatur

Torx 20

hot limit ring (10)

Do not overtighten ! 

stop ring (3)

valve steam 
driver (2)

screw (1)

valve stem
driver (2)

(9)

4

Installation of the trim set and setting the hot limit stop

Close shut-off valves:
-

Once shower enclosure is completed, remove the finished wall template.

-

If the valve body is equipped with service stop valves close the hot and
cold water supplies. Otherwise, shut the supply at the nearest source.

Remove valve stem driver and stop ring:
-

Remove the screw (1) to remove the plastic valve stem driver (2).

-

Remove  stop ring (3) note position.

Turn cartridge for back-to-back installation:
-

Remove the four cover screws (4) and the valve cover (5) with O-ring (6).

-

Pull the cartridge out. Do not damage the O-ring seals.

-

Rotate the cartridge 180° turning it upside down. Place it into the valve
body. Note position of hot ("H") and cold ("C") markings on the cartridge:
"H" hot will now be on the right and "C" cold on the left. Two alignment pins
located on the rear of the cartridge must sit in the locating holes within the
valve body. Cartridge is correctly engaged when pushing the cartridge, it
will not rotate.

Installation Back-to-back

(if applicable)

Installation of the escutcheon (8):

Install escutcheon screws (7) into valve cover posts.
Slide the escutcheon (8) over the screw heads and rotate escutcheon
counterclockwise.
Tighten the screws (7) so the escutcheon is firmly pressed against the wall and
does not rotate.  Do not overtighten!

!

-

Put the O-ring on the valve cover. Make sure the surface of the valve
cover, on which the O-ring will sit, and the O-ring are both clean.

-

Position the valve cover with stop post facing down. Seat the cover to the
body. Do not pinch the O-ring. The assembly should fit together with a
minimum of pressing force.

-

Tighten up the cover screws diagonally, first lightly and then more
firmly.

Fix stop ring on closed position:
-

Close the valve by turning the cartridge stem clockwise.

-

Position the stop ring on the stem as shown in figure 4.

-

Install plastic stem driver (2) with screw (1).

Setting hot limit stop:

A)

Rotate escutcheon driver stem (9) counterclockwise until a desired and safe
hot water temperature is reached (recommened maximum is 110°F / 43°C)

B)

Place the hot limit ring (10) over the splines on the stem (9) with the hot limit
ring resting against the stop post on the escutcheon.
Closing the valve while rotating the stem (9) clockwise until it stops,

Install the handle.

À

Á

Â

Ã

À

Á

Â

À

Á

Â

Ã

À

Á

3

Содержание MARLINO 802 141

Страница 1: ...leanerscontainaggressive acidic corrosive chemicals or abrasives which will harm the finishandcauseoperationalproblems C Use of these products voids the manufacturer s warranty Operation A counterclockwise rotation opens the valve beginning with cold water Preventing accidental scalding An adjustable hot limit stop reduces risk of exposure to extremely hot water Clockwise rotation of the handle cl...

Страница 2: ...kinstallation Dimensions Back to back installation In back to back installations cartridge must be rotated 180 to ensure proper valve operation 3 port valve shower only Position valve with outlet up Finished wall must be within the dimensions shown on finished wall template 4 port valve tub and shower Position valve with shower outlet marked S up and the tub outlet marked T down Finished wall must...

Страница 3: ...hin the valve body Cartridge is correctly engaged when pushing the cartridge it will not rotate InstallationBack to back ifapplicable Installation of the escutcheon 8 Install escutcheon screws 7 into valve cover posts Slide the escutcheon 8 over the screw heads and rotate escutcheon counterclockwise Tighten the screws 7 so the escutcheon is firmly pressed against the wall and does not rotate Do no...

Страница 4: ...rrectly set Either the hot or cold side is not fully pressurized Debris caught inside the inlet of the cartridge No engagement between escutcheon and plastic driver Improper installation Remedy Rotate cartridge as described in Back to back installation Allow approximately 3 5 minutes to drain column or push lever on tub spout to the tub fill position Reset the hot limit stop ring as described in r...