© KWB – Kraft und Wärme aus Biomasse GmbH
IM Easyfire 10/2008
Page
179
18.2 Hydraulic diagrams
18.2 Hydraulic diagrams
Basic module with weather-sensitive control system,
expansion module and buffer as long-term buffer
System description:
The hydr. system consists of the boiler circuit, the buffer switched as long-term buffer (VAR 2), and the distributor.
The return flow boost is executed via a thermal mixing valve (28) on at least 55 °C. The base module for DHWC
& buffer control is equipped with a weather-sensitive control system for 2 heating circuits (option), and is combined
with a bus-capable heating circuit expansion module (25). Two heating circuits are equipped with analogue room
control units (option), the other two heating circuits are equipped with digital room control units (option) for remote
control.
Basic settings menu
Parameter
Settings
Return flow boost
Thermal valve
Network settings
Boiler
External 2
Heat to target 2
Power output
Heating mode
Heating circuit /
heating circuit 0
Room sensor
Boiler / 0
Outdoor sensor
Boiler
Function
No
Group no.
0
Heating circuit /
heating circuit 1
Room sensor
DRCU 1
Outdoor sensor
Boiler
Function
Yes
Group no.
0
Heating circuit /
heating circuit 2
Room sensor
Boiler / 2
Outdoor sensor
Boiler
Function
Yes
Group no.
0
Heating circuit /
heating circuit 3
Room sensor
DRCU 2
Outdoor sensor
Boiler
Function
Yes
Group no.
0
Heating circuit /
heating circuit 4
Room sensor
HCM 1 / 1
Outdoor sensor
Boiler
Function
Yes
Group no.
0
DHWC / DHWC 0
Function
Yes or No
Group no.
0
DHWC / DHWC 1
Function
No
Group no.
0
Buffer / buffer 0
Function
VAR 2
Buffer / buffer 1
Function
No
Digital remote control /
Outdoor sensor
Boiler
Digital remote control 1
Heating circuit
1 - 2 or 1 - 4
DHWC
0 - 0
Buffer
0 - 0
Digital remote control /
Outdoor sensor
Boiler
Digital remote control 2
Heating circuit
3 - 4 or 1 - 4
DHWC
0 - 0
Buffer
- - -
Hardware
Heating circuit modules
1
Digital remote control
2
Plug-in modules
Off
Comments: None
Subject to change!
Tech. data sheet HYD-USP-MBEH0010_b, sheet 2/2, date: 12-02-07 StHo
MA-Easyfire 10.2008_EN.indd 179
MA-Easyfire 10.2008_EN.indd 179
30.03.2009 13:32:18 Uhr
30.03.2009 13:32:18 Uhr
Содержание Easyfire
Страница 1: ...Biomass Heating Systems Pellet boilers KWB Easyfire 10 30kW Installation and Maintenance Manual...
Страница 45: ......
Страница 59: ......
Страница 63: ......
Страница 69: ......
Страница 77: ......
Страница 95: ......
Страница 107: ......
Страница 113: ......
Страница 143: ......
Страница 161: ......
Страница 181: ......
Страница 213: ......
Страница 218: ...Notes...