8. CABLE REQUIREMENTS
Pin
Color
1
Orange
/White
2
Orange
3
Green
/White
4
Blue
5
Blue
/White
6
Green
7
Brown
/White
8
Brown
8.1 REQUIREMENTS FOR CAT5E/6/7 CABLES
A Cat5e/6/7 cable should meet the following requirements:
• The pins are connected 1:1.
Caution:
the cable pairs must be twisted to EIA/TIA- 568A (rare)
or EIA/TIA-568 B (common) pairs.
• Erroneous assignments cannot be found with a simple cable tester.
• The pins for the green pair of wires are not adjacent to one other.
• The cable must at the very least meet the CAT5 specifications and be suitable for Gigabit
transmission.
• The cable should meet one of the following standards: Class D ISO/IEC 11801:2002
or EN 50173-1:2002. Schema EIA/TIA-568 B.
• Only use shielded installation cable with min. cross section of 24 AWG throughout
the length.
• The shield should be contiguous and connected to both ends. A shielded patch cable is
allowed for connection to the device.
Schema EIA/TIA-568 B
8.2 REQUIREMENTS FIBER CABLES
8.2.1 MULTI-MODE (STANDARD)
A Multi-Mode fiber cable should meet the following requirements:
• Maximum length should be 500 m. The ME1-F includes a fiber Multimode – SFP
Module which allows a transmission distance of up to 500 m.
• Dedicated fiber connection cable type Duplex Multimode 50/125μ (OM3), LC
connector
8.2.2 SINGLE-MODE (OPTIONAL)
A fiber Single-Mode – SFP Module cable should meet the following requirements:
• Up to 20 km transmission distance.
• Requires dedicated fiber connection: cable type Duplex Singlemode with LC connector
A fiber Single-Mode – SFP Module BiDi cable should meet the following requirements:
• Up to 20 km transmission distance.
• Requires dedicated fiber connection: cable type Singlemode with LC connector
Wavelength (λ) of 850 nm in multi-mode or 1310 nm TX -1550 nm RX in single-mode
8. CABLE REQUIREMENTS
Содержание EASYLINE masterEasy