Installation Guide  

TracNet

 

H90

Содержание TracNet H90

Страница 1: ...Installation Guide TracNet H90...

Страница 2: ......

Страница 3: ...Test the System 28 Connect Vessel Network Devices 29 Connect the Vessel Phones 30 Educate the Customer 31 Appendices Terminating LMR 240 Cable 32 Connecting Pigtail Cables to the Antenna Cable 36 App...

Страница 4: ...becomes damaged and or no longer functions normally disconnect it from vessel power secure it from unintended operation and contact KVH Technical Support see Technical Support on page 1 All repairs o...

Страница 5: ...or nut driver 3 4 socket for mounting bolts and 7 8 socket or wrench for mounting nuts recommended torque 35 40 ft lbs 47 54 N m Light hammer and center punch Adhesive tape Self vulcanizing tape or e...

Страница 6: ...0 Mounting Structure Requirements Make sure the mounting surface is flat level within 1 and wide enough to accommodate the antenna s base Also make sure that the structure is strong enough to withstan...

Страница 7: ...415 MPa minimum yield For more details refer to the Pedestal Specs Wizard www kvh com pedestalspecs Note The ship s crew is responsible for fabricating and installing the pedestal Figure 3 Pedestal an...

Страница 8: ...dar high power radio transmitters including transmit frequency power transmitter beam properties and the reflective properties of nearby surfaces consider the following general guidelines Mount the KV...

Страница 9: ...oise The Hub is designed for mounting in a standard equipment rack It requires 1U of available space Be sure the front panel will be easily accessible to the user Leave enough room behind the rear pan...

Страница 10: ...g hole locations you marked in Step 2 Later you will insert four 1 2 13 bolts through these holes to secure the antenna to the mounting surface Figure 8 Antenna Mounting Holes Layout Cut Out the Cable...

Страница 11: ...not remove the four inner bolts that secure the internal antenna assembly to the baseplate Figure 10 Shipping Bolts Antenna Bottom View 3 Close both service hatches Secure each hatch using the hex lat...

Страница 12: ...rrect length and diameter specified in Figure 12 to ensure proper engagement Make sure there is no gap between the end of the cable jacket and the start of the connector When determining cable lengths...

Страница 13: ...the six 6 32 captive screws securing the cable cover to the base Set the cover aside in a safe place Figure 14 Cable Cover Attach Second Foam Seal If Needed If you routed the cable through a hole und...

Страница 14: ...e antenna s connector 5 Seal the cable connection with self vulcanizing tape or equivalent Figure 17 Connecting the Cable to the Antenna 6 Secure the antenna cable near the antenna to relieve stress T...

Страница 15: ...ed 1 2 13 bolts to prevent galling 5 At each baseplate mounting hole place a 1 2 flat washer on a 1 2 13 bolt and insert the bolt into the hole from above Figure 21 Mounting the Antenna Side View 6 Se...

Страница 16: ...move the lift brackets and hardware and set them aside Figure 22 Removing the Lift Brackets Note Save the brackets and bracket hardware in case the antenna needs to be moved in the future 10 Install e...

Страница 17: ...can be nested for extended depth connect them end to end using the supplied M5 screws and nuts not shown in the figure Figure 25 L Rail Installation 2 Attach the supplied strain relief bracket to the...

Страница 18: ...a tool or overtighten 4 Secure the antenna cable to the strain relief bracket Also make sure the cable will not get bent or twisted near the BDU s connection which can put additional stress on the co...

Страница 19: ...z input rate Note To supply both the required heading and the optional position to the BDU you can either connect an NMEA 0183 talker that transmits both messages or connect two devices using an NMEA...

Страница 20: ...some vessels So check with the customer or ship s electrician and get permission before you run the system on two phase power Also be sure to ground the system as explained below If two phase power is...

Страница 21: ...VDC A higher voltage indicates a dangerous floating ground condition 6 Repeat the previous step with the BDU powered on looking for the same measured result Figure 33 Power Wiring WARNING Failure to g...

Страница 22: ...satellite Also make sure no errors are reported in the header see example in Figure 36 Figure 35 VSAT Status Page on Front Panel Figure 36 Error Message on Front Panel Example IMPORTANT During startu...

Страница 23: ...BDU serial no 3 Start the web browser and enter https kvhonboard com Note If the setup wizard is not displayed try entering https 192 168 5 1 which is the default IP address You might need to bypass...

Страница 24: ...e Screen Note After setup is complete you must log into the web interface as an administrator to make further changes to the system settings Assign an Administrator Password At the first page of the w...

Страница 25: ...and DHCP END range As you ll see on the next page the BDU s Ethernet ports can be split into two LANs for connecting to either the VSAT High speed HS channel or Unlimited Use UL channel You can modify...

Страница 26: ...peed and Unlimited Use VSAT data speeds and rates refer to the airtime rate sheet For details on external VoIP devices see External VoIP Devices Optional on page 30 Figure 44 Setting the Port Configur...

Страница 27: ...associated password s To add a network not shown in the list select Advanced Wi Fi Settings Select Then enter the network name security protocol and password Figure 45 Configuring WAN Settings When yo...

Страница 28: ...select CHOOSE FILE Note This single software update file applies to both the antenna and the belowdecks unit i e Hub 3 Select the software update file you saved on your laptop Be sure it is the AC BD...

Страница 29: ...ill need to enter in clockwise order beginning and ending azimuths that define the outer boundaries of the zone s relative to the antenna s forward arrow which should be pointing toward the bow Figure...

Страница 30: ...oogle com over the VSAT connection 7 Turn on all other electronic equipment above deck within the proximity of the antenna if possible Verify that both the KVH system and the electronic equipment cont...

Страница 31: ...AN settings at the Setup Wizard the High speed HS LAN has a gateway of 192 168 5 1 and assigns IP addresses in the 192 168 5 50 150 range and the Unlimited Use UL LAN has a gateway of 192 168 6 1 and...

Страница 32: ...minal adapter KVH part no 19 0504 Enables up to two additional lines Crew Calling Gateway KVH part no 72 0349 Provides a dedicated phone line for crew members and charter guests to place ship to shore...

Страница 33: ...ntenna must have a clear view of the sky to communicate via satellite Common causes of blockage include masts trees buildings and bridges Dirt buildup on the radome can also affect communications Figu...

Страница 34: ...e cutting the cable can deform the end gently round the end of the cable Also make sure the center conductor is centered within the cable Figure 60 Reshaping the Cable 3 Place the metal ferrule onto t...

Страница 35: ...This removes the cable jacket from the end of the cable exposing the braid and dielectric Figure 63 Stripping the Cable Jacket Figure 64 Cable Stripped Exposing Dielectric 6 Using the DBT U deburr to...

Страница 36: ...iate crimp tool crimp the ferrule in place Crimp as close to the connector body as possible Figure 69 Crimping the Ferrule onto the Cable 11 Slide the heat shrink sleeve over the connector body and he...

Страница 37: ...ble When you are done the heat shrink should extend from the rear of the connector to the cable jacket This forms a weather tight seal Figure 71 Properly Terminated LMR 240 RF Cable 12 Using a multime...

Страница 38: ...later use The heat shrink will protect the connection between the antenna cable connector and the pigtail cable connector 2 Fill half of the inner body of the antenna cable connector with the supplie...

Страница 39: ...the cable type you would like to use is not listed below or at the Cable Wizard please contact KVH Technical Support Note All cables listed below are 50 ohm cables except where noted otherwise Cable T...

Страница 40: ...onnect the NMEA 0183 talker to the adapter s RS422 input Then connect the adapter to the laptop s USB port Figure 74 Connecting a NMEA 0183 Talker to a Laptop 2 Start PuTTY and specify the laptop s po...

Страница 41: ...39 TracNet H90 Installation Guide Wiring Diagram Appendix E Wiring Diagram...

Страница 42: ...quipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation...

Страница 43: ......

Страница 44: ...847 3327 Fax 1 401 849 0045 E mail info kvh com KVH Industries A S EMEA Headquarters Kokkedal Denmark Tel 45 45 160 180 Fax 45 45 160 181 E mail info emea kvh com KVH Industries Pte Ltd Asia Pacific H...