Chapter 2: Installing the system
36
Placing the terminal
2.5 Placing the terminal
2.5.1 Overview
Because the terminal comes in two versions, the following description
contains
•
one section for the TracPhone terminal and
•
one section for the TracPhone 19” Rack Terminal
2.5.2 Where to place the TracPhone terminal
Temperature conditions
The terminal must be placed in a ventilated area with free space around all
sides of the unit, except the bottom side.
Ambient temperature range is –25°C to +55°C.
If the terminal is installed in a location where the ambient temperature may
exceed 45°C, we recommend placing the terminal where unintentional contact
is avoided. If the maximum ambient temperature does not exceed 45°C, the
terminal can be placed in a public area.
Grounding access
The terminal is designed with a case for bulkhead or desktop installation.
The case is equipped with mounting brackets, making it possible to secure the
unit on a bulkhead.
Содержание FB250
Страница 13: ...Table of contents xii ...
Страница 77: ...Chapter 3 Connecting power 64 Connecting power ...
Страница 105: ...Chapter 5 Starting up the system 92 Operating the system ...
Страница 129: ...Chapter 6 Service and repair 116 Replacing modules in 34 3052B antenna ...
Страница 139: ...Chapter 7 Troubleshooting 126 Logging of events ...
Страница 147: ...Appendix B Technical specifications 134 FB500 antenna B 2 3 Antenna outline dimensions FB500 in 26 66 cm dome ...
Страница 148: ...Appendix B Technical specifications FB500 antenna 135 BBBB Technical specifications FB500 in 35 89 cm dome ...
Страница 154: ...Appendix B Technical specifications FB250 antenna 141 BBBB Technical specifications FB250 in 19 48 cm dome ...
Страница 165: ...Appendix B Technical specifications 152 TracPhone terminal ...
Страница 197: ...Glossary 184 ...