background image

Kvaser USBcan Pro 5xHS User’s Guide

Copyright 2015-2018 Kvaser AB, Mölndal, Sweden
http://www.kvaser.com

Printed Monday 12

th

February, 2018

We believe that the information contained herein was accurate in all respects at the time of printing.
Kvaser AB cannot, however, assume any responsibility for errors or omissions in this text. Also note
that the information in this document is subject to change without notice and should not be construed
as a commitment by Kvaser AB.

Содержание USBcan Pro 5xHS

Страница 1: ...18 We believe that the information contained herein was accurate in all respects at the time of printing Kvaser AB cannot however assume any responsibility for errors or omissions in this text Also note that the information in this document is subject to change without notice and should not be construed as a commitment by Kvaser AB ...

Страница 2: ...Kvaser USBcan Pro 5xHS User s Guide 2 23 This page is intentionally left blank Kvaser AB Mölndal Sweden www kvaser com ...

Страница 3: ... USB connector 8 3 3 CAN channels 9 3 4 Power supply 9 3 5 LED Indicators 9 3 6 Troubleshooting 10 4 Appendices 11 4 1 Definitions of LED states and colors 11 4 2 Start and stop of t programs 13 4 3 Technical data 14 4 4 CAN connectors 14 4 5 CAN bus termination 16 4 6 Updating the firmware 16 4 7 Kvaser MagiSync 17 5 Disposal and Recycling Information 19 6 Legal acknowledgements 20 6 1 Usage warn...

Страница 4: ...About this manual This manual is intended for Kvaser USBcan Pro 5xHS users This document contains a description of the hardware s properties and general instructions for connecting the device to a computer Kvaser AB Mölndal Sweden www kvaser com ...

Страница 5: ...igure 1 Kvaser USBcan Pro 5xHS Kvaser USBcan Pro 5xHS is a small yet advanced portable multi channel CAN to USB real time interface that handles transmission and reception of standard and extended CAN messages on the CAN bus with a high time stamp precision The Kvaser USBcan Pro 5xHS is compatible with applications that use Kvaser s CANlib Kvaser AB Mölndal Sweden www kvaser com ...

Страница 6: ... compliant with ISO 11898 2 up to 1 Mbit s Fully compatible with J1939 CANopen NMEA 2000 R and DeviceNet Kvaser MagiSync automatic time synchronization see Section 4 7 Kvaser MagiSync on Page 17 for more details Simultaneous operation of multiple devices Includes 5 channel breakout cable 2 3 Interface Kvaser USBcan Pro 5xHS provides a CAN bus interface through a standard USB interface 2 4 The t pr...

Страница 7: ...ed File I O Functions fileOpen fileClose fileGets fileReadBlock filePuts fileWriteBlock fileSeek fileDelete Predefined XML Functions xmlOpen xmlClose xmlGet Predefined t Program Related Functions scriptLoad Predefined Logger Related Functions filterDropMessage loggerStatus loggerStart loggerStop Other Predefined Functions timeGetDate Table 2 Functionality in the t language v3 2 that is not support...

Страница 8: ...The firmware is downloaded and installed directly on the Kvaser USBcan Pro 5xHS and the driver is installed on the host computer The latest version of the driver and firmware can be downloaded from www kvaser com download The driver is installed by running the file kvaser_drivers_setup exe For information on how to upgrade the firmware see Section 4 6 Updating the firmware on Page 16 3 2 USB conne...

Страница 9: ...gradation and timing issues that if necessary can be mitigated using shorter cable segments combined with hubs that amplify the signal and handle delays on a per cable basis 3 3 CAN channels The Kvaser USBcan Pro 5xHS has five CAN Hi Speed channels in a single 26 pin HD D SUB CAN connector see Figure 3 See Section 4 4 CAN connectors on Page 14 for pinout information Figure 3 CAN connector on Kvase...

Страница 10: ... Kvaser Device Guide in the Control Panel to verify that the computer can communicate with the Kvaser USBcan Pro 5xHS If the firmware version shown is all zeros there are communication problems If the LEDs are not flashing or do not light up at all check the power supply Kvaser AB Mölndal Sweden www kvaser com ...

Страница 11: ...mitted Flash The LED is lit up for a very short time A single flash may be hard to see and a continuous set of flashes will look the same as On Slow Blink The LED is repeatedly turned On and Off The On and Off phase is equal in time Fast Blink The LED is repeatedly turned On and Off but with a higher frequency than Slow Blink The On and Off time is still equal On The LED is constantly emitting lig...

Страница 12: ... Slow Waver Green Yellow All Slow Blink Yellow Power problem2 Table 4 Yellow Power LED shows problems in Interface mode Traffic LED Description Off Idle no CAN traffic Flash Yellow CAN message received or sent Flash Red Error frame received All Fast Blink Yellow Firmware update is in progress Fast Blink Red CAN channel is error passive On Red 3 CAN overrun Table 5 Traffic LED shows CAN bus status ...

Страница 13: ...ing itself which this section describes Read the Kvaser t Programming Language guide that can be downloaded at www kvaser com download for more information The on start event will be triggered in the Kvaser USBcan Pro 5xHS when any of the following occurs When a t program is started using the CANlib API kvScriptStart When a t program is started from another t program The on stop event will be trig...

Страница 14: ...ode Yes Kvaser MagiSync Yes PC interface USB Hi Speed Power consumption max 500 mA Hardware configuration Done by software Plug Play Software requirements Windows Vista or later For other operating systems contact Kvaser support Dimensions 68 x 170 x 23 mm for body incl strain relief Weight 150 g 320g including HD26 5DS9 Splitter Operating temperature 40 C to 85 C Storage temperature 40 C to 85 C ...

Страница 15: ...el 5 6 Not connected 7 Not connected 8 4 Not used 9 Not connected 10 9 Not used 11 7 CAN_H channel 1 12 7 CAN_H channel 2 13 7 CAN_H channel 3 14 7 CAN_H channel 4 15 7 CAN_H channel 5 16 Not connected 17 Not connected 18 4 Not used 19 3 GND channel 1 20 3 GND channel 2 21 3 GND channel 3 22 3 GND channel 4 23 3 GND channel 5 24 Not connected 25 Not connected 26 Not connected Table 7 Pin configura...

Страница 16: ... For laboratory or testing use the exact value of the termination resistors is not always critical Sometimes a single terminator is sufficient For production proper termination is essential If you see error frames on the bus you should check the termination To save yourself a lot of trouble always terminate the CAN bus properly 4 6 Updating the firmware For the Kvaser USBcan Pro 5xHS to communicat...

Страница 17: ...each PC to bus interface uses its on board clock to set the time stamps Kvaser MagiSync is an innovative way to synchronize several different Kvaser USB interfaces You do not need external cables you get instant synchronisation when you connect the MagiSync enabled Kvaser USB device Figure 8 An example setup where all devices are synchronized via MagiSync For this to work the Kvaser USB interfaces...

Страница 18: ... 18 23 Figure 9 Not all devices are synchronized via MagiSync in this setup When connected correctly all units are synchronized achieving a high precision virtual clock accurate to the microsecond Kvaser AB Mölndal Sweden www kvaser com ...

Страница 19: ...ation When this product reaches its end of life please dispose of it according to your local environmental laws and guidelines For information about Kvaser s recycling programs visit http www kvaser com en kvaser recycling policy html Kvaser AB Mölndal Sweden www kvaser com ...

Страница 20: ...DAMAGE TO EQUIPMENT DEVICES OR THE SURROUNDING ENVIRONMENT WITH THIS DEVICE YOU MAY POTENTIALLY CAUSE A CHANGE IN THE OPERATION OF THE SYSTEM MODULE DEVICE CIRCUIT OR OUTPUT TURN ON OR ACTIVATE A MODULE DEVICE CIRCUIT OUTPUT OR FUNCTION TURN OFF OR DEACTIVATE A MODULE DEVICE CIRCUIT OUTPUT OR FUNCTION INHIBIT TURN OFF OR DEACTIVATE NORMAL OPERATION MODIFY THE BEHAVIOR OF A DISTRIBUTED PRODUCT ACTI...

Страница 21: ...0130 00779 6 The object of the declaration described above is in conformity with the relevant Union harmoni sation legislation Chemical substances REACH Regulation EC No 1907 2006 Electromagnetic Compatibility EMC Directive 2014 30 EU RoHS recast Directive 2011 65 EU Waste Electrical Electronic Equipment WEEE Directive 2012 19 EU The following harmonised standards and technical specifications have...

Страница 22: ...ely to cause harmful interference in which case the user will be required to correct the interference at his her own expense 6 3 Patents Copyrights and Trademarks All trademarks are the property of their respective owner Windows is a registered trademark of Microsoft Corporation in the United States and other countries Adobe the Adobe logo and Reader are either registered trademarks or trademarks ...

Страница 23: ...5 08 11 Minor textual changes 1 2 2015 10 29 Minor textual changes 1 3 2016 02 04 Minor textual changes 1 4 2017 01 09 Updated compliance text added link to patents 2 0 2017 08 24 Updated EU Declaration of Conformity 2018 01 28 Kvaser Device Guide has replaced Kvaser Hardware 2018 01 28 Kvaser Device Guide has replaced Kvaser Hardware 2 1 2018 01 29 Kvaser Device Guide has replaced Kvaser Hardware...

Отзывы: