Replacing Tooling in the Back Section
3-41
KVAL 990-F4 Service Manual
Changing the Bore Drill
1.
Remove Dust Collection
Guard
2.
Use the shaft wrench and
collet wrench to remove the
bit on the pre-drill or router
assemblies. See photo.
When loosening the collet, it
may tighten up, crack again
and continue.
3.
Inspect and clean collet
.
4.
Insert the new bit into the assembly.
5.
Before tightening the collet assembly, adjust the bit depth. Bottom out the bit and
pull the bit up about 1.4''.
6.
Lightly tighten and torque to correct value. For torque values,
Note:
Make sure the arbor is not bottomed out in the back of the motor. If it is, the
arbor will not tighten and will damage the collet or other machine parts.
Note:
The figure shows the cover off for training purposes.
Collet Wrench
(PN: 15-00-ER32)
Shaft Wrench (1 5/8 '')
(PN: WRENCH026)
Содержание 990-F4