background image

5

ESP4000  ·  G

etting S

tar

ted

ESP4000 · Getting Started 

IT IS RECOMMENDED THAT THE VOLTAGE SUPPLY BE WITHIN THE RATED VOLTAGE WINDOW. THIS ENSURES THAT AC 
VOLTAGE VARIATIONS FROM THE SERVICE ENTRY - OR PEAK VOLTAGE DROPS DUE TO CABLE RUNS - DO NOT CAUSE THE 
AMPLIFIER TO CYCLE ON AND OFF OR CAUSE DAMAGE TO THE POWER SUPPLY.

Voltage Requirements

The ESP4000 operates safely and without audio discontinuity if the AC voltage stays within the operating window of 100V-130V 
in 115V mode, 200V-250V when working in 230V mode and 220-270V when working in 250V mode at 50 or 60Hz. 

CAUTION: IF THE ON LED DOES NOT ILLUMINATE OR THE SYSTEM DOES NOT RESPOND TO AUDIO INPUT, REMOVE AC 
POWER IMMEDIATELY. VERIFY THAT THE VOLTAGE IS WITHIN THE PROPER RANGE. IF THE PROBLEM PERSISTS, PLEASE 
CONTACT KV2 AUDIO OR AN AUTHORIzED SERVICE CENTER.

If the voltage drops below the low boundary of its safe operating range, the amplifier will shut down if the voltage does not 
rise above the low boundary before storage circuits are depleted. How long the amplifier will continue to function during 
brownout depends on the amount of voltage drop and the audio source level during the drop. If the voltage increases 
above the upper boundary of the range, the power supply can be damaged.

FOR BEST PERFORMANCE, THE AC CABLE VOLTAGE DROP SHOULD NOT ExCEED 10 VOLTS, OR 10 PERCENT AT 115 VOLTS 
AND 5 PERCENT AT 230 VOLTS.

Make sure that even with the AC voltage drop, the AC voltage always stays within recommended operating ranges.  
The minimum electrical service amperage required by an ESP4000 amplifier is the sum of each amplifiers maximum continuous 
rms current. An additional 50 percent above that amperage is recommended to prevent peak voltage drops at the service entry.

The Power Connector

The ESP4000 requires grounded outlets. It is very important that the amplifiers AC supply be properly grounded in order to 
operate safely and properly. Use the PowerCon AC cable-wiring diagram overleaf to create international or special-purpose 
power connectors:

Power connector assembly

Current Requirements

Each of the ESP4000's power supply inputs require approximately 20 Amps max at 115V AC for proper operation. This means 
that both of the ESP4000's power supplies must be powered from an individual 20 A breaker when running in 115V mode.

When operating in 230 V mode each of the ESP 4000's power supply inputs requires approximately 10 Amps max. This allows 
a complete ESP4000 to be powered from one 20 A breaker at at 230 V.

The ESP4000 presents a dynamic load to the AC mains, which causes the amount of current to fluctuate depending on quiet 
or loud operating levels. Since different cables and circuit breakers heat up at varying rates, it is essential to understand the 
types of current ratings and how they correspond to circuit breaker and cable specifications.

The maximum long-term continuous current is the maximum rms current during a period of at least ten seconds. It is used to 
calculate the temperature rise in cables in order to select a cable size and gauge that conforms to electrical code standards. It 
is also used to select the rating for slow-reacting thermal breakers.

The burst current is the maximum rms current during a period of approximately one second, used to select the rating of 
most magnetic breakers and to calculate the peak voltage drop in long AC cables according to the formula: V pk (drop)= I 
pk x R (cable total).

The ultimate short-term peak current is used to select the rating of fast reacting magnetic breakers. Use the table below as  
a guide when selecting cable gauge size and circuit breaker ratings for your operating voltage.

Содержание ESP4000

Страница 1: ...n is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source Our aim is to create audio products that absorb you place you within the performance and deliver a listening experience beyond expectations ...

Страница 2: ...it is intended for use in a 19 rack Follow the mounting instructions When a rack on wheels is use use caution when moving the loaded rack to avoid injury from tipping over 14 Install the product only with both front and rear supports 15 Unplug this amplifier during lightning storms or when unused for long periods of time 16 Do not connect a ESP4000 s output in parallel or series with any other ESP...

Страница 3: ...Mounting 4 Cooling 4 AC Power Requirements 4 AC Power 4 Voltage Requirements 5 The Power Connector 5 Current Requirements 5 AC Cable Colour Coding 6 Safety Summary 6 Features 7 Front Panel 7 Rear Panel 8 Running the ESP4000 in Bridge Mono Mode 9 Specifications 10 Warranty Service 11 Notes 12 Contents ...

Страница 4: ... can be dangerous This is a very highpowered device that can put out high voltages and sizeable currents Always use safe operating techniques with the ESP4000 FOR YOUR SAFETY READ THE IMPORTANT PRECAUTIONS SECTION AS WELL AS THE INPUT OUTPUT AND POWER CONNECTION SECTIONS OF THIS MANUAL ESP4000 part number KVV 987 215 250V KVV 987 208 230V KVV 987 214 115V Front Panel Rear Panel Side Panel Applicat...

Страница 5: ...ent requirements as well as electrical safety issues is critical to the safe operation of the ESP4000 Cooling The ESP4000 has a comprehensive cooling system featuring chassis sealed PCB board mounting and shock mounted speed controlled fans This means that the cooling system never drives air across PCB boards connectors or components ensuring prolonged electronic component lifespan and minimizing ...

Страница 6: ... at the service entry The Power Connector The ESP4000 requires grounded outlets It is very important that the amplifiers AC supply be properly grounded in order to operate safely and properly Use the PowerCon AC cable wiring diagram overleaf to create international or special purpose power connectors Power connector assembly Current Requirements Each of the ESP4000 s power supply inputs require ap...

Страница 7: ...ole threewire grounding mains receptacle Mains plug shall remain easy to operate Amplifier must be powered from the same phase The receptacle must be connected to a fuse or circuit breaker Connection to any other type of receptacle poses a shock hazard and may violate local electrical codes Do not allow water or any foreign object to get inside the amplifier Do not put objects containing liquid on...

Страница 8: ...hannel This feature is active so long as the switch is left un pressed The RMS limiting is deactivated when the switch is depressed 4 Power On Thermal These are dual colour LED s When green they indicate that the Power Switch is ON and that channel of the amplifier is powered up When red they indicate that channel has overheated and shut down The unit will Auto Reset after it cools down to a safe ...

Страница 9: ...e ESP4000 uses one connector per two channels Both must be connected to operate all four channels of the ESP4000 Half of the channels will be fully functional if only one is connected They accept standard PowerCon terminated AC Mains cables 4 Fans The cooling fans operate continuously while the ESP4000 is on An internal temperature sensor increases the speed of the fans during high temperature con...

Страница 10: ...negative side of the high powered loudspeaker load This has correctly connected the high powered loudspeaker load to both CH1 CH2 ready to be driven in Bridge Mono mode To ensure the amplifier channels are working together correctly in this mode you must feed the Main Input Signal into ONLY CH1 before linking across to CH2 with a special phase reversal lead To make this lead you must modify a stan...

Страница 11: ...ded 1000W 800W RMS Out Power 16Ω bridged 600W RMS Out Power 8Ω bridged 1000W RMS Out Power 4Ω bridged 1600W RMS 2000W short term Signal Input Input Channels XLR Input Sensitivity 1 55V Input Impedance 20kΩ balanced Signal Output XLR Through Speaker Input Speaker Input 4x Binding posts Neutrik Speakon Features Level Control to 0dB Loudness bass enhancement 6dB 60Hz RMS Limiter On Off Indicators Pow...

Страница 12: ...returned to an authorized distributor service centre or shipped directly to our factory Because of the complexity of the design and the risk of electrical shock all repairs must be attempted only by qualified technical personnel If the unit needs to be shipped back to the factory it must be sent in its original carton If improperly packed the unit may be damaged To obtain service contact your near...

Страница 13: ...ESP4000 Notes 12 ESP4000 Notes ...