background image

 
 
 

The menu button accesses the following settings or modes:

 

ProLaser 4 Quick Reference Guide 

RCMP Configuration

 
 

 

 

 

Head-Up Display

 

 

 

 

 

 

6

 

ProLaser 4 Menus

 

 

Distance

 

Sets min/max range limits to target vehicle for school 
and work zone enforcement. Fire the LASER at the 
desired target or use up/down arrows to enter values.  
Press enter to set min/max ranges. Any target measured 
outside the range limits will not be displayed. 

Set Direction

 

Sets target direction discrimination to Approaching 
only,  Receding only, or Both.

 

DIF-TEST

 

Two-target, differential distance accuracy test mode.

 

Continuous/ 
Single

 

Sets enforcement mode to continuous target 
measurement or single shot mode (option).

 

Units 

Select between mph/km/h; mph/knots; or km/h/knots (option).

HUD

 

Options

 

Toggle Range in HUD on/off.  Select from four aiming

 

reticles.

 

Events

 

Displays last 100 locked targets with Speed, Range 
and  Direction with date and time stamp.

 

Set 
Time/Date

 

Set date and time in 24 hour format (option).

 

Stopwatch

 

Average speed over distance enforcement mode (option).

 

Self-Test

 

Press the test button to run internal accuracy tests.

 

HUD Alignment 
Test

 

Place the ProLaser 4 in range mode.  Select an isolated 
target ~100 feet away and sweep HUD horizontally and 
vertically across target.  Listen for audio tone and verify 
aiming reticle on target coincides with tone and range 
measurement in HUD.

 

Differential

 

Distance Test

 

Select two targets ~ 50 and 100 feet away.  Target each 
when prompted and verify range accuracy.

 

 

KSI p/n 006-0966-12 Rev 3 

 (800)4KUSTOM 

(800) 458-7866

 

www.kustomsignals.com

Отзывы: