29
3BA00205 • 2020-10-28 • Rev. 5
Ersa i-CON
VARIO 2
Functional description
6.3.3
Min. temp. / Max. temp.
The Min. temp. and Max. temp. parameters determine the temperature
range in which the tool’s temperature can be adjusted.
The tool’s temperature can be changed directly in operating mode by turning i OP. This
temperature can be reduced by adjusting the Min. temp. / Max. temp. parameters.
6.3.4
Calibration temperature
This function serves the purpose of calibrating the soldering tip
temperature. It enables the balancing of display value and actual
tip temperature. The adjustable calibration range is −70 ... +50 °C /
−126 ... +90 °F.
The exact calibration procedure is described in the chapter 6.3.7
[Calibrating the i‑CON VARIO 2].
If you do not have appropriate measuring equipment for this measurement, please
enter “0” into this parameter field.
6.3.5
Setting the size of the hot air nozzle i‑TOOL AIR S
The air quantity and temperature of the i‑TOOL AIR S can be adapted to
the hot air nozzle and the soldering process used. Once the i-TOOL AIR
S is connected to the station, the option [Air nozzle] will appear. After
pressing the i-OP one can adjust the type of the hot air nozzle used.
Pressing again confirms the selection.