10
Service Manual
For internal use only
6.2
Functions
Minute counting device with an acoustic signal
The hood is fitted with a minute counting device which gives off an acoustic signal in the zero posi-
tion. Press the MENU button to make a setting (the symbol will appear on the display) and then
press the OK button. 00.00 will blink on the display.
The – and + buttons are used to set the required number of minutes (from 1 to 99). When the but-
tons are pressed for a longer period the minutes will be shown in rapid succession. Press the OK
button to confirm the setting and then press the MENU button to end the process.
When the number of minutes set has expired an acoustic signal will sound and the display will blink
with the corresponding indication. To switch off the function press the OK button (if the OK button
is not pressed the function will automatically be switched off after 5 minutes).
To switch the minute counting device off at any given moment press the MENU and OK buttons
simultaneously (reset).
Timer
The hood is fitted with an automatic stop device which switches the hood off after 5 (or 10) minutes.
When the timer is switched on the hood will automatically be switched off after 5 (or 10) minutes.
Press the MENU button to switch the timer on and then press the – and + buttons until the corre-
sponding symbol appears on the display. Confirm with the OK button. The – and + buttons can be
used to set the timer at either 5 or 10 minutes. Press the MENU button to exit the menu.
Clock
To activate the clock function or to adjust the clock time, press the MENU button and then buttons
– and + until the 4 numbers blink on the display. Enter the time of day with buttons – and + and
confirm with the OK button.
To exit the menu, press the MENU button. Press the MENU and the “OK” (reset) buttons simulta-
neously to switch off the clock function.
Sensor sensitivity
The degree of sensitivity of the sensor can be adjusted according to individual requirements. Press
the MENU button to adjust the sensitivity and then press the – and + buttons until the corresponding
symbol appears on the display. Then press the OK button and select the required degree of sensi-
tivity between 1 and 9. Confirm with “OK”.
To exit the menu, press the MENU button.
Interior temperature display
In order to show the interior temperature on the display, press the MENU button, then press the
– button (or the + button) repeatedly until the display shows “in 18°C” or a similar indication. Confirm
with the OK button. The interior temperature is measured with a sensor (supplied) which can be in-