on a direct line: about 15 m).
9. Grease filter alarm: After approximately 30 hours of operation, the display will show the symbol
, indicating that it
is time to clean the grease filters. Once the filters have been cleaned, restart the hour count by pressing the “MENU”
and “ok” (reset) keys at the same time.
10. Charcoal filter alarm: After approximately 120 hours of operation, the display will show the symbol
, indicating that
it is time to replace the charcoal filters. Once the filters have been replaced, restart the hour count by pressing the “MENU”
and “ok” (reset) keys at the same time.
LIST OF SYMBOLS
SPEED (4 speeds + extra-high speed)
AUTOMATIC SENSOR
19.38
CLOCK
MINUTE COUNTER
In 18°C
INSIDE TEMPERATURE
Out 15°C OUTSIDE TEMPERATURE
GREASE FILTER CLEAN
CHARCOAL FILTER REPLACEMENT
TIMER
ON / OFF
LIGHTS
RESET (COMBINATION OF KEYS)
MENU SELECTION
CONFIRMATION KEY
LESS
MORE
Cleaning the grease filters
: special attention must be given to the grease filters which must be periodically cleaned,
whenever the grease filter alarm trips. For instructions of the filter Alarm, refer to the Controls paragraph. Remove the
filters as shown in para. 1 and wash with neutral detergent.
Replacing the charcoal filters
: if the filtering version appliance is used, the charcoal filters will have to be periodically
replaced when the charcoal filter alarm trips. For instructions on the filter Alarm, refer to the Controls paragraph. Removing
the charcoal filter/s: first of all, remove the grease filters; push the catch inwards (Fig. 3) and remove the charcoal filter
from its case (Fig. 17). Reposition a new charcoal filter of the same type inverting the operations.
Lighting
: To replace the halogen lamps, open the cover by prising in the slots (Fig. 19). Replace with lamps of
the same type.
WARNING: Do not touch the new lamp with bare hands.
Inside temperature measuring device
: The hood is supplied with a device for measuring the inside temperature that
can be positioned anywhere in the room. The temperature measured is shown on the hood control panel display. If this
function is not active, use the controls on the hood as follows: press the “MENU” key, then press the - or + key until
the display shows “In 18°C” or similar; then press “ok”.