18
H2-50-02
For internal use only
7.
Settings and conversion to a different type of gas
7.1
Replacing injectors
The cooking zone burners can be adapted for different types of gas by mounting main injectors in
compliance with the type of gas used. The burner heads will first of all need to be removed. Then use a
straight spanner “B” to screw out the injector “A” and replace it with an injector in accordance with the
type of gas used.
The primary air does not need to be adjusted for the cooking zone burners.