Kuma Stoves K-SEQ Скачать руководство пользователя страница 9

 

9

Section 

3.1

 –Residential Free Standing Installation 

 

INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION 

AND OPERATING INSTRUCTIONS ONLY.  WHILE MOST ANYONE WITH BASIC 

CARPENTRY SKILLS CAN SUCCESSFULLY AND SAFELY INSTALL THEIR KUMA WOOD 

STOVE, IT IS HIGHLY RECOMMENDED THAT IT IS INSTALLED BY A QUALIFIED 

PROFESSIONAL WHO IS PROPERLY TRAINED AND LICENSED–PREFERABLY AN NFI 

CERTIFIED (NATIONAL FIREPLACE INSTITUE) EXPERT. 

 

CAUTION:

  The Structural integrity of the home floor, walls, and ceiling/roof must be maintained.  Use 

additional bracing if required.  Never cut a load bearing wall or engineered truss, use elbows if necessary to 
offset the pipe. 
 

CAUTION:  NEVER INSTALL A STOVE IN A SLEEPING ROOM. 

DO NOT INSTALL THIS UNIT 

IN A MOBILE OR MANUFACTURED HOME 

 
Free Standing Installation: 
 
Step 1: Determining the stove location: 

 
 

When choosing a stove location there are a few things that should be considered. 

 

1.

 

Try to choose a location that is centrally located in the house. 

2.

 

Try to choose a location that will be easy to access from your wood storage area. 

3.

 

Survey the roof area above and around the location of the chimney exit.  Be sure there are no 
dormers, roof valleys or any other roof irregularities that could cause difficulty when trying to set 
and seal the roof flashing. 

4.

 

If possible, survey the attic area above and around the location of the chimney.  Be sure there are 
no major obstructions such as plumbing, heating ducts, electrical wires, phone cables, etc.  Also 
check the crawl space below and around the stove location for the same obstructions. 

 

 

STEP 2:  Installing the chimney. 
 
Use only 8” Class A solid fuel chimney that has been U.L. safety tested for wood stoves (type 103 HT) 
 
IMPORTANT:  These instructions are a very basic guideline for the steps to install your chimney.  
For complete instructions, refer to the installation manual that came with your chimney.  Chimney 
installation instructions are usually located in the box with the chimney cap or chimney support 
components. DO NOT mix different brands of chimney components. If you have any questions about 
the installation of your chimney, please contact the dealer where you purchased your stove. 
 
CAUTION:  Inspect all chimney components for damage.  Do not use any damaged chimney 
components. 
 
 Installing the chimney  
 
CAUTION:  Inspect all chimney components for damage.  Do not use any damaged chimney 
components. 
 

1.

 

Familiarize yourself with the clearances of the stove for the configuration in which you have 
chosen to install, i.e. corner installation or straight wall installation (see section 6).  Notice the 
clearances listed for the chimney, this will help you determine the location of the hole in the 
ceiling.  Note:  On metal roofs in snow regions, consideration must be given to snow loads above 

Содержание K-SEQ

Страница 1: ...KUMA STOVES Rathdrum ID USA MODEL K SEQ Sequoia Tested to UL1482 Report 123 S 04 2 Testing performed by Omni Test Laboratories INSTALLATION AND OPERATING INSTRUCTIONS SAVE THESE INSTRUCTIONS Rev 4 18 12 ...

Страница 2: ...with a quality product that will last a lifetime If you ever have a problem with your stove we will do what is needed to get it resolved and keep you warm You may have noticed a portion of the Bible enclosed in your owner s packet It is a small gift for you Our faith in Jesus Christ is very important to us and we have that faith because there is hope in heaven That hope comes from the message of t...

Страница 3: ...ailure to properly install and maintain your wood stove can result in an unsafe condition Contents Section 1 Safety Precautions Section 2 Catalyst Information Section 3 1 Free Standing Installation Instructions Section 3 2 Insert Installation Instructions Section 4 Wood Burning Operation Instructions Section 5 Maintenance Section 6 Installation Clearances and Diagrams Section 7 Troubleshooting Sec...

Страница 4: ...4 ...

Страница 5: ...5 Section 1 Safety Precautions ...

Страница 6: ...professional advice We recommend having existing chimneys cleaned and inspected by a qualified professional prior to the installation of your new Stove 10 NOTE ALL MINIMUM CLEARANCE REQUIREMENTS TO COMBUSTIBLES Installation must comply with minumum clearances as listed in this manual see section 6 11 Do not operate this stove with the door in the open position 12 This stove must be connected to a ...

Страница 7: ...7 at www nfpa org or call them toll free at 1 800 344 3555 Your local building dept may also have information regarding NFPA code 211 EXCERPT FROM NFPA 211 ...

Страница 8: ...be stem must be 3 16 diameter and between 4 and 5 in length Condar brand model 3 12 1 Optional Probe installation To install the probe remove the metal button on the top plate of the stove near the flue Insert the probe through the top plate and into the firebox Reading the Probe Follow the instructions in section 4 to build and maintain a fire During normal operation see section 4 the probe shoul...

Страница 9: ...flashing 4 If possible survey the attic area above and around the location of the chimney Be sure there are no major obstructions such as plumbing heating ducts electrical wires phone cables etc Also check the crawl space below and around the stove location for the same obstructions STEP 2 Installing the chimney Use only 8 Class A solid fuel chimney that has been U L safety tested for wood stoves ...

Страница 10: ...anada the hearth must be at least 54 deep For Canadian clearances refer to the listing tag on the back of the stove STEP 4 Setting the stove and connecting to the chimney 1 Attach the legs before setting the stove on the hearth Once the legs are attached set it gently on the hearth using cardboard to protect the hearth 2 Position the stove on the hearth according to the clearances shown on the dia...

Страница 11: ...e it cleaned and inspected by your dealer or a chimney professional Use and install liner kits that are approved to UL 1777 only Tools and materials Required 1 7 16 wrench 2 Flat blade screwdriver 3 KA SEQSURR Fireplace surround kit 4 Bricks or a metal roller to level stove in fireplace you may use the leveling bolts provided in the fireplace surround kit for most applications 5 Unfaced fiberglass...

Страница 12: ...et the insert on the hearth using a dolly Make sure the dolly is rated to carry at least 515 lbs and has a strap to secure the stove to the dolly 6 Insert the unit way into the fireplace then use a roller or unscrew the leveling bolts to level the stove 7 Carefully slide the insert all the way to the back wall of the fireplace Make sure you do not bend the leveling bolts while sliding the stove Yo...

Страница 13: ...e pulled all the way out towards yourself during start up It should remain open long enough to achieve a medium to high burn rate about 15 20 minutes It may also be necessary to crack the door to allow extra air during start up never leave the stove unattended with the door open Usually a normal fire start up to produce a good coal bed will produce sufficient temperatures to begin catalytic combus...

Страница 14: ...ate draft Additional instructions and information 1 Build your fires directly on the firebrick Using a grate will allow too much air to the coal bed and will result in incomplete combustion of the wood Using a grate can also leave charred pieces of wood after the fire has gone out 2 Use only the best grade of dry wood available Wood should be seasoned for 1 full year prior to being used Split wood...

Страница 15: ...the creosote is not removed on a regular basis a chimney fire can occur which can damage the chimney and or stove Therefore the importance of regular chimney maintenance cannot be emphasized enough Gasket Replacement Every year or as needed 1 Gaskets need to be checked at least once a year The gaskets on your stove are designed to keep unwanted air out of the firebox Neglecting these gaskets can c...

Страница 16: ... as needed 1 If you have determined that the catalyst needs to be replaced contact you nearest dealer for parts and service Use the parts list in section 8 for ordering a replacement catalyst 2 Replacement Steps a Remove stove pipe or pull out insert to gain access to the stove flue If removing insert is not practical you can access baffle fasteners through the stove door Instructions for this fol...

Страница 17: ...17 Catalyst replacement diagram Baffle clip Hold down clamp Catalytic Bypass plate Baffle Bypass rod ...

Страница 18: ...s diagram for the following installations 1 Residential installation with the stove in a corner using double wall pipe For single wall pipe refer to figure 2 Hearth ALL CLEARANCES SHOWN IN INCHES ALL CLEARANCES ARE MINIMUMS HEARTH CLEARANCES SHOWN IN 19 19 10 10 8 8 8 18 ...

Страница 19: ...e following installation 1 Residential installation with the stove in a corner using single wall pipe For double wall pipe refer to figure 1 Hearth ALL CLEARANCES SHOWN IN INCHES ALL CLEARANCES ARE MINIMUMS HEARTH CLEARANCES SHOWN IN 24 24 15 15 8 8 8 18 ...

Страница 20: ...llowing installations 1 Residential installation with the stove on a sraight wall using double wall pipe For single wall pipe refer to figure 4 ALL CLEARANCES SHOWN IN INCHES ALL CLEARANCES ARE MINUMUMS HEARTH CLEARANCES SHOWN IN Hearth 16 13 10 27 8 8 8 18 ...

Страница 21: ...llowing installations 1 Residential installation with the stove on a straight wall using single wall pipe For double wall pipe refer to figure 3 ALL CLEARANCES SHOWN IN INCHES ALL CLEARANCES ARE MINIMUMS HEARTH CLEARANCES SHOWN IN Hearth 25 18 15 36 8 8 8 18 ...

Страница 22: ... diagram for the following installations 1 Installation into a masonry fireplace ALL CLEARANCES SHOWN IN INCHES ALL CLEARANCES ARE MINIMUMS 18 20 30 Combustible Mantle Option 1 Leveling bolts Option 2 Roller Chimney liner 18 30 8 ...

Страница 23: ...ibles must be maintained per manufacturer s instructions on chimney pipe and stove pipe connectors This stove is not approved for installation in manufactured mobile homes rain cap 3 minimum 2 minimum 10 Roof brace Residential Home Installation Residential Home Installation Storm collar 8 Chimney Sections Attic Insulation Shield Support Box Cross Framing 2 MINIMUM air space around chimney 2 MINIMU...

Страница 24: ...nstallation Use this diagram for the installation of your stove into an alcove All other hearth section 2 and stove clearance requirements section 6 must be maintained 62 Minimum Opening 90 Minimum Height 36 Maximum Depth ...

Страница 25: ...25 Sequoia dimensional drawings 7 Recessed Flue 8 30 22 75 32 5 10x14 75 22 5 10 ...

Страница 26: ...d air 2 Chimney and or the chimney cap needs to be cleaned Your chimney should be checked and cleaned if necessary every few months Even a small amount of build up can cause a draft restriction for example inch of build up on the side wall of an 8 chimney reduces the effective area of the chimney by about 20 Pay close attention to the chimney cap especially if it has a screen Screened chimney caps...

Страница 27: ...ir supply to the stove If ash has built up around the air sliders clean with a brush and or slight air pressure 6 Atmospheric conditions Occasionally barometric episodes occur that affect draft thereby affecting stove performance If your stove has been working fine and performance drops suddenly this is most likely the cause and will usually go away within a few days 7 Your fuel load may be too sm...

Страница 28: ...firebrick 2 KR DOORGASKET Replacement door gasket includes glue 3 KR DOORPIN3 Set of 2 door pins 4 KR GLASS2 Replacement glass includes gasket 5 KR GLASSGASKET Replacement glass gasket 6 KR GLASSRETAIN2 Glass retaining ring includes new screws 7 KR SEQBAFFLE Sequoia baffle No catalytic bypass plate or rod 8 KR SEQBAFFLESET Includes baffle catalytic bypass rod and plate 9 KR SEQBRICKSET Sequoia fir...

Страница 29: ...may also contact Kuma stoves directly at 1 888 714 5294 or contact us online at kumastoves com When calling you will need to have your proof of purchase the model name and the serial number of your stove When calling please remember that shipping and handling costs are not covered under this warranty Warranty Exclusions This Warranty does not cover 1 Changes in the color of the surface of the stov...

Страница 30: ...30 Section 10 EPA Information ...

Отзывы: