Field bus communication error messages
11.6
Fuses and LED indicators on the CI3 board
11.6.1
CI3 Standard board
Overview
Effects
Causes
Remedy
Communication via diagnostic
interface not possible
Data cable, periphery faulty
Check data cable, periphery
Diagnostic interface on field
bus card defective
Exchange field bus card
Error message "xxxxx I/O
driver configuration error"
Field bus card incorrectly con-
figured
Check the configuration
Field bus card cannot be initial-
ized
Exchange field bus card
Incorrect configuration of the
file IOSYS.INI
Check entries in IOSYS.INI
After inserting the field bus
card: no display, controller
does not boot (Stop 0)
Field bus card defective
Exchange field bus card
The controller "hangs" after ini-
tialization of the field bus card
Field bus card defective
Exchange field bus card
No external power supply for
slave when controller switched
off
Interbus filter defective or not
correctly connected
Exchange Interbus filter (if
fiber-optic cable)
External power supply input on
IBS card defective
Exchange Interbus card
Fig. 11-1: CI3 Standard board fuses and LEDs
Содержание KR C2 edition05
Страница 8: ...8 157 V3 3 11 07 2007 KRC AD KRC2ed05 BA en KR C2 edition05...
Страница 42: ...42 157 V3 3 11 07 2007 KRC AD KRC2ed05 BA en KR C2 edition05 2 9 2 KCP connector X19 Connector pin allocation...
Страница 72: ...72 157 V3 3 11 07 2007 KRC AD KRC2ed05 BA en KR C2 edition05 Connector pin allocation...
Страница 76: ...76 157 V3 3 11 07 2007 KRC AD KRC2ed05 BA en KR C2 edition05...
Страница 84: ...84 157 V3 3 11 07 2007 KRC AD KRC2ed05 BA en KR C2 edition05...
Страница 157: ...157 157 V3 3 11 07 2007 KRC AD KRC2ed05 BA en...