Exit “emptying” by pressing button 4 .
When exiting setup screen “Emptying”, all drives stop immediately.
Chambers filled with salt or refined salt, must be emptied before a longer operating pause, as salt clumps within few
days because of humidity. There is danger of “tunneling”, i.e. salt is spread only until the screw channel is empty,
because no more salt is provided from the chambers.
Daily statistics
You get to the daily statistics via the user menu.
The menu line with the entry “Daily statistics” must be chosen by the left turning knob
, the menu line will be
highlighted in dark color.
By pressing button 6 the page with the daily statistics will be displayed.
The daily statistics can be reset by the user by means of button 1; all entries of the daily statistics will be deleted.
Exit the daily statistics with button 4
without deleting values.
Complete statistics
The complete statistics indicate the total quantity and counter readings of the spreader, it can not be reset. You get
to the complete statistics via the user menu.
The menu line with the entry “Complete statistics” must be chosen by the left turning knob , the menu line will
be highlighted in dark color.
By pressing button 6 , the page with the complete statistics is displayed.
By pressing button 4 , you exit complete statistics.