19
burns. If a cabinet storage is to be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5" (12.7cm) beyond the bo
tt
om of the
cabinets.
Connect Range to Gas Supply
1. Install a manual gas line shut
-off
valve in the gas line in an easily accessed
location
outside the range in the gas piping external to the appliance for the purpose of turning
on or shu
tti
ng
off
gas to the appliance.
2. Install male
1
/
2
inch
flare
union adapter to
1
/
2
inch NPT internal thread elbow at inlet
of regulator. On models equipped with standard twin burners, install the male pipe
thread end of the
1
/
2
inch
fl
are union adapter to the
1
/
2
inch NPT internal thread at inlet
of pressure regulator. Use a wrench on the regulator
fittin
g to avoid damage.
3. Install male
1
/
2
inch or
3
/
4
inch
flare
union adapter to the NPT internal thread of the
manual shut-o
ff
valve, taking care to secure the shut-o
ff va
lve to keep it from turning.
4. The gas supply pressure for checking the regulator
setting
is 6 in.w.c. (Nature Gas) and
11 inch.w.c. (LP gas) connect
fl
exible gas line connector to the regulator on the range.
Position
range to permit conne
ction
at the
shut-off
valve.
When all co
nnections have been
made, make sure all range controls are in the posi
ti
on
and turn on main gas supply valve.
5. Leak
testing
of the appliance shall be conducted according to the manufacturer’s
instructions. Us
e some soap water (50% water and 50% soap) or a leak detector at all
joints and
connections
to check for leaks in the system. Do not use a
flam
e to check for
gas leaks.
FOR MORE DETAILS AND INFORMATION, PLEASE VISIT OUR WEBSITE