(1) Front mower link bushing (2 places)
(2) Rear mower link bushing (4 places)
(3) Front mower link
(4) Rear mower link
6. Checking the battery condition
DANGER
To avoid the possibility of battery explosion:
For the refillable type battery, follow these
instructions:
• Do not use or charge the refillable type battery
if the fluid level is below the [LOWER] (lower
limit level) mark. Otherwise, the battery
component parts may prematurely deteriorate,
which may shorten the battery's service life or
cause an explosion.
• Check the fluid level regularly and add distilled
water as required so that the fluid level is
between the [UPPER] and [LOWER] levels.
• When the battery is being activated, hydrogen
and oxygen gases in the battery are extremely
explosive. Keep open sparks and flames away
from the battery at all times, especially when
charging the battery.
WARNING
To avoid serious injury or death:
• Batteries, battery posts, terminals and related
accessories contain lead, lead compounds and
other chemicals known to the State of California
to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
• Never remove the battery cap while the engine
is running.
• Keep electrolyte away from eyes, hands and
clothes. If you are spattered with electrolyte,
wash it away completely with water immediately
and get medical attention.
• Wear eye protection and rubber gloves when
working around the battery.
NOTE :
• The factory-installed battery is a non-refillable
type.
If the battery is weak, charge the battery or
replace it with a new one.
IMPORTANT :
• Mishandling the battery shortens the service life
and adds to maintenance costs.
The original battery is maintenance free, but
needs some servicing.
If the battery is weak, the engine will be difficult
to start and the lights will be dim. It is important
to check the battery periodically.
• When exchanging an old battery with a new
one, use a battery of equal specifications (as
described in the following table).
Battery
type
Volts (V)
Reserve
capacity
(min)
Cold
cranking
amps
Normal
charging
rate (A)
51R
12
80
430
4.5
Regarding non-accessible maintenance-free type
batteries:
Maintenance-free,
non-accessible
batteries
are
designed to eliminate the need to add water. Yet the
volume of electrolyte above the plates may eventually
become depleted due to abnormal conditions such as
high heat or improper regulator settings. Use LCD
monitor or a voltmeter to check the state of charge.
(See the following reference chart to determine if
charging is necessary.)
Battery voltage
Reference state of charge
12.6
100% (full charge)
12.4
75%
12.2
50%
12.0
25%
11.8
0%
6.1 How to read indicator
Check the battery condition by reading the indicator.
Green
Specific gravity of electrolyte and quality of elec-
trolyte are both in good condition.
Black
Battery needs charging.
White
Battery needs replacing.