![Kubota Z723 Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/kubota/z723/z723_operators-manual_2008732070.webp)
53
PERIODIC SERVICE
ENGLISH
B
Cleaning Engine Cooling Areas
The engine cooling areas should be cleaned every 100
hours operation or every 1 year, whichever comes first.
To avoid serious injury:
A
Make sure engine is cool to the touch before
removing shrouds.
A
Always shield eyes and face from air deposits
and objects.
1. Remove outer fan guard by removing its 3 mounting
bolts.
2. Remove inner fan guard by removing its 4 mounting
bolts.
3. Remove oil cooler by removing its 2 mounting bolts.
4. Remove fuel pump by removing its 2 mounting bolts.
5. Unplug engine wire harness from voltage regulator.
6. Remove green grounding bolt from voltage regulator.
7. Remove breather filter by removing its 2 mounting
bolts.
8. Remove blower cover by removing its 5 remaining
mounting bolts.
9. Clean all areas that were previously covered by the
blower cover with compressed air. Remove all dust,
dirt, and debris.
10.Reinstall all parts in the reverse order of the above
procedure.
(1) Outer Fan Guard and bolts
(2) Inner Fan Guard and bolts
(3) Oil Cooler
(4) Fuel Pump
(5) Voltage Regulator and Grounding Bolt
(6) Blower cover
(7) Breather Filter
Содержание Z723
Страница 7: ......
Страница 13: ...SAFE OPERATION 6 ENGLISH 5 DANGER WARNING AND CAUTION LABELS ...
Страница 14: ... 7 SAFE OPERATION ENGLISH ...
Страница 15: ...SAFE OPERATION 8 ENGLISH ...
Страница 16: ... 9 SAFE OPERATION ENGLISH ...
Страница 19: ...SERVICING OF MACHINE 2 ENGLISH 1 ROPS serial No ...
Страница 53: ...MAINTENANCE 36 ENGLISH PERIODIC SERVICE CHART LABEL 1 Part No K3811 6551 ENGLISH 2 Part No K3811 6552 SPANISH ...