REGULAR CHECKS AND MAINTENANCE WORK
76
Stop the engine, then remove the key and wait until it has
cooled down completely.
1. Open the drain plug on the bottom of the radiator and
drain coolant completely. Should a recovery tank be
equipped, disconnect the line from the tank floor and
then open the drain shutoff-valve.
2. To clean, rinse the radiator with water.
3. Close the drain plug, and fill the radiator and the
recovery tank with coolant fluid. Let the engine idle for
about 5 min. Stop the engine and remove the key.
4. Check the coolant level of recovery tank and add the
coolant if necessary.
5. The shipped machine has been filled with 50% anti-
freeze solution.
A
Do not operate the engine without coolant.
A
To fill the radiator system and the recovery tank, use
fresh water and anti-freeze fluid.
A
When the anti-freeze is mixed with water, the anti-
freeze mixing ratio must be less than 50%.
A
Tighten the radiator cap properly. If the cap is loosely
or not properly fitted, overheating of the engine can
result due to coolant fluid loss.
B
Replacing Fuel Hoses and Hose Clamps
Replace the hoses and clamps.
(See "Checking Fuel Line and Intake Air Line" in "EVERY
200 SERVICE HOURS")
(1) Drain plug
(1) Radiator cap
(1) Recovery tank
(A) "FULL"
(B) "LOW"
Cooling water
Canopy
Approx. 4.3 L
Cabin
Approx. 4.7 L
Radiator
recovery tank
Approx. 0.85 L
(1) Fuel lines
(2) Clamp bands
Содержание U35-4
Страница 16: ...SAFE OPERATION 8 6 DANGER WARNING AND CAUTION LABELS ...
Страница 17: ... 9 SAFE OPERATION ...
Страница 18: ...SAFE OPERATION 10 ...
Страница 19: ... 11 SAFE OPERATION ...
Страница 20: ...SAFE OPERATION 12 ...
Страница 21: ... 13 SAFE OPERATION ...
Страница 24: ...DEALER SERVICE 2 1 Engine serial No ...
Страница 66: ...44 EXCAVATOR OPERATION ...
Страница 114: ...92 LIFTING CAPACITY ...
Страница 115: ...93 LIFTING CAPACITY ...