REGULAR CHECKS AND MAINTENANCE WORK
52
ANNUAL SERVICING
B
Electrical Wiring and Fuses
Check the terminals periodically for proper connections.
Loose wiring or damaged cables can cause improper
functioning or short circuiting of the electrical system.
Check wiring and replace damaged components
immediately. If a fuse blows out soon after having been
replaced, contact your nearest KUBOTA dealer. Never
use a fuse other than specified.
B
Checking the Electrical Circuit
Check the electrical circuitry for disconnections, shorts or
loose terminals.
BIENNIAL SERVICING
To avoid personal injury:
A
Do not loosen the radiator cap before the
radiator has cooled down sufficiently. Then
only loosen the cap and allow enough time for
the pressure in the system to be released. Now
remove the cap completely.
B
Replacement of Radiator Hoses and Hose
Clamps
Replace radiator hoses and hose clamps every two years.
If the hoses are swollen, hard or cracked, they must be
replaced earlier.
B
Changing Radiator Coolant
(In case of long-life coolant fluid)
Stop the engine then remove the key and wait until it has
cooled down completely.
1. Open the drain plug or shutoff-valve on the bottom of
the radiator and drain coolant completely.
2. To clean, rinse the radiator with water.
3. Close the drain plug or shutoff-valve and fill the
radiator and the recovery tank with coolant fluid. Let
the engine idle for about 5 min., stop the engine and
check the coolant level then remove the key.
4. The machine has been shipped filled with 50% anti-
freeze solution.
(1) Radiator hoses
(2) Hose clamps
(1) Drain plug
(1) Radiator cap