3. If the reference values are not indicated, the sensor
is damaged.
Resistance
(Sensor termi-
nal - Sensor
body)
Reference
value
Float at up-
per-most posi-
tion (Full)
2.75 to 3.15 Ω
Float at lower-
most position
(Empty)
97 to 113 Ω
4.12.5 Checking coolant temperature
sensor connector voltage
1. Disconnect the 2P connector from the coolant
temperature sensor after turning the main switch
OFF
.
2. Turn the main switch
ON
and measure the voltage
with a voltmeter across the 2 terminal (W/Y) and the
chassis.
3. If the voltage differs from the reference voltage, the
wiring harness, fuse or coolant temperature gauge
is damaged.
Voltage
2 terminal
(W/Y) - Chas-
sis
4.9 to 5.1 V
4.12.6 Checking coolant temperature
sensor continuity
(1) Coolant temperature sensor
(2) Coolant
1. Measure the resistance with an ohmmeter across
the sensor 1 terminal and 2 terminal.
2. If the reference value is not indicated, the sensor is
damaged.
Resistance (1 ter-
minal - 2 terminal)
Reference val-
ue
Approx. 11.08 Ω at
120
℃
(248
℉
)
Approx. 18.36 Ω at
100
℃
(212
℉
)
Approx. 31.8 Ω at 80
℃
(176
℉
)
Approx. 81.1 Ω at 50
℃
(122
℉
)
SERVICING
4. Checking and adjusting
8. ELECTRICAL SYSTEM
BX1880,BX2380,BX2680,RCK60B-23BX,RCK54-23BX,RCK48-18BX,RCK60D-26BX,RCK54D-26BX
8-45
KiSC issued 03, 2019 A
Содержание ,RCK60B-23BX
Страница 19: ...1 INFORMATION KiSC issued 03 2019 A ...
Страница 42: ...2 GENERAL KiSC issued 03 2019 A ...
Страница 111: ...3 ENGINE KiSC issued 03 2019 A ...
Страница 190: ...4 TRANSAXLE KiSC issued 03 2019 A ...
Страница 255: ...5 FRONT AXLE KiSC issued 03 2019 A ...
Страница 274: ...6 STEERING KiSC issued 03 2019 A ...
Страница 291: ...7 HYDRAULIC SYSTEM KiSC issued 03 2019 A ...
Страница 344: ...8 ELECTRICAL SYSTEM KiSC issued 03 2019 A ...