Maintenance
136
!
Check the electrolyte level in the battery, adding distilled water if required.
!
Remove the negative terminal cover and take off the cable clamp. Put the clamp to the side so that contact
with the negative terminal is excluded.
!
Remove the positive terminal cover.
!
Connect the battery charger to the battery according to the instructions of the charger manufacturer. Choose
the normal (gentle) charging method.
!
Clean the battery after charging and replenish the electrolyte, if necessary.
!
Check the acid density with a hydrometer. The acid density should be between 1.24 and 1.28 kg/L. If the acid
density differs considerably among the individual cells of a battery, the battery probably has a defect. Check
the affected battery with a battery tester and contact trained personnel.
Installing/uninstalling and replacing the battery
!
Make the battery accessible.
!
Remove the negative terminal cover and take off the cable clamp. Put the clamp to the side so that contact
with the negative terminal is excluded.
!
Remove the plus terminal cover and take off the cable clamp. Put the clamp to the side so that contact with
the positive terminal is excluded.
!
Remove the battery retainer and lift the battery out of the swivel frame.
!
Before installation, cover the battery terminals and cable clamps with petroleum jelly.
!
Install the battery in the swivel frame and fasten it with the battery retainer. Check the battery for tightness
!
do not operate the excavator with a loose battery.
!
Connect the positive cable clamp to the positive terminal (+) of the battery, install the positive terminal cover.
!
Connect the negative terminal (-) of the battery, install the negative terminal cover.
When disconnecting and connecting the battery, always observe the specified order
!
risk of short
circuit.
When disconnecting and connecting the battery, always observe the specified order
!
risk of short
circuit.
When replacing the battery, always install a battery of the same type with the same power rating and
the same dimensions.