AC Power supply (Option)
The unit accepts AC supply from 115 to 230 V at the terminals 24 and 25. The power
consumption depends on the level of the supply voltage with approx. 3VA and the
additional current required at the auxiliary voltage output.
Devices with option AC can also be supplied with a DC voltage between 18 and 30 VDC
at terminals 1 and 2.
3.10
Relay Output (Option)
Two relay outputs with potential-free changeover contacts are available at terminal 27,
28, 29 and 30, 31, 32. Switching conditions can be set in the PRESELECTION MENU. The
switching states are displayed (display with unit and status bar) as K1 and K2.
AC-switching capacity max. 250 VAC/max. 3 A / max. 750 VA
DC-switching capacity max. 150 VDC /max. 2 A / max. 50 W
Wiring of the relay outputs: