20
WATER PUMP, COOLING SYSTEM
207
B01567-10
(EXC
‑
F EU/AUS/BR, EXC-F SIX DAYS, XCF-W)
–
Position the motorcycle upright.
–
Place a suitable container under the water pump cover.
–
Remove screw
. Take off radiator cap
.
–
Completely drain the coolant.
–
Mount and tighten screw
with a new seal ring.
Guideline
Screw, water pump cover
M6
10 Nm
(7.4 lbf ft)
20.5
Refilling coolant
Warning
Danger of poisoning
Coolant is poisonous and a health hazard.
–
Coolant must not come into contact with the skin, eyes, or clothing. If contact occurs with the eyes, rinse with water imme-
diately and contact a physician. Immediately clean contaminated areas on the skin with soap and water. If coolant is swal-
lowed, contact a physician immediately. Change clothing that is contaminated with coolant. Keep coolant out of reach of
children.
M00196-10
Main work
–
Make sure that the screw
is tightened.
–
Stand the vehicle upright.
–
Pour coolant in up to measurement
above the radiator fins.
Guideline
10 mm (0.39 in)
Coolant
1.2 l (1.3 qt.)
Coolant (
Coolant (mixed ready to use)
–
Refit the radiator cap.
Finishing work
–
Take a short test ride.
–
Check the coolant level. (