KTI Networks KSC-361 Скачать руководство пользователя страница 1

-1- 

 

 

 

 

KSC-361 

 

Industrial   

Ethernet to Serial 

Media Converters 

 

 

Firmware Rev

1.00

 up 

 

User’s Manual 

 

 

 

 

 

 

 

 

DOC.170725 

Содержание KSC-361

Страница 1: ... 1 KSC 361 Industrial Ethernet to Serial Media Converters Firmware Rev1 00 up User s Manual DOC 170725 ...

Страница 2: ...rmission from KTI Networks Inc KTI Networks Inc reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact 15F 7 No 79 Sec 1 Hsin Tai Wu RD His chih New Taipei City Taiwan Fax 886 2 26983873 E mail kti ktinet com tw URL http www kt...

Страница 3: ...e interference that may cause undesired operation CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EN 55022 Class A EN 61000 6 4 EN 61000 3 2 EN 61000 3 3 EN 61000 6 2 IEC 61000 4 2 IEC 61000 4 3 IEC 61000 4 4 IEC 61000 4 5 IEC 61000...

Страница 4: ...C Power Jack 21 2 5 3 PoE via RJ 45 22 2 6 Alarm Relay Output 23 2 7 Reset Button 24 2 8 Making RJ 45 Port Connections 25 2 9 Making SFP Fiber Connection 26 2 10 Selection of Copper RJ 45 or Fiber SFP 27 2 11 Setting DIP Switches 27 2 11 1 4 Wire 2 Wire Bus 28 2 11 2 Receiver Terminator 28 2 11 3 ADC 29 2 11 4 Line Bias 29 2 12 Making RS 232 Connection 30 2 12 1 Making PC Connection via COM Port 3...

Страница 5: ...38 5 3 System Host Configuration 39 5 4 Application Configuration 40 5 5 TCP Control Configuration 41 5 5 1 Selecting Application Mode 43 5 6 UDP Control Configuration 44 5 6 1 UDP Master Configuration 44 5 6 2 UDP Slave Configuration 45 5 7 Serial Port Control Configuration 46 5 8 Event Notification 48 5 8 1 Notification via SNMP Trap and Email 48 5 8 2 Notification Events 49 5 9 Statistic Overvi...

Страница 6: ... drop Network 58 A1 3 RS 485 Multi drop Network 58 A1 4 RS 485 Half duplex 2 wire Network 59 A1 5 RS 485 Full duplex 4 wire Network 59 Appendix 2 VCOM Program for Windows 60 A2 1 Functions of VCOM 60 A2 2 Installing the VCOM Program 60 A2 3 VCOM Program Operation 62 A2 4 Alternative Solution beside VCOM Program 64 ...

Страница 7: ...verters Two models are described in this documentation They are Model Number KSC 361 S2 KSC 361 S4 Ethernet Interface 10 100Mbps RJ 45 10BASE T 100BASE TX 10 100Mbps RJ 45 10BASE T 100BASE TX Fiber Interface SFP 100BASE FX SFP 100BASE FX Serial Interface DB9 RS 232 Terminal Block RS 422 RS 485 Photo ...

Страница 8: ...wer voltage support DC 8V 60V Powered over Ethernet PoE enabled through RJ 45 interface Alarm relay output for power failure port link down and TCP server connection failure Application support for remote COM port serial server and client over TCP reverse telnet Remote COM driver support for Windows PC Web based and serial based console configuration Event notification over SMTP and SNMP traps 1 2...

Страница 9: ... 9 KSC 361 S2 Top Panel KSC 361 S4 Front panel KSC 361 S4 Top Panel ...

Страница 10: ... 802 3u 100Base TX Connector Shielded RJ 45 jack Pin assignments Auto MDI MDI X detection Configuration Auto negotiation or software control Transmission rate 10Mbps 100Mbps Duplex support Full Half duplex Flow control Enabled Network cable Cat 5 UTP up to 100 meters Pin assignment MDI X Pin 10 100 1 RX 2 RX 3 TX 4 5 6 TX 7 8 PoE PD Class 3 Ethernet 100M Fiber SFP Slot Compliance IEEE 802 3u 100Ba...

Страница 11: ...pport Up to 230K baud Connector Shield Connect to chassis ground Connection Distance 15 meters Overvoltage Protection Cutoff if over 28V RS 422 485 Serial Interface KSC 361 S4 Interface RS 422 RS 485 Connector Flange terminal block 5P Signal Type Balanced differential lines Data Speed 230Kbps Standard EIA 485 EIA 422 Overvoltage Protection Cutoff if over 28V Isolation Galvanic isolated Pin assignm...

Страница 12: ...control 7 RX B1 RX line bias 8 RX B2 RX line bias DC IN Terminal Block Connector Flange terminal block 5P Contacts Isolated to frame ground Pin Marking Remark 1 DC Direct power input 2 DC Direct power input 3 NO Alarm relay NO Normal Open output 4 Common Alarm relay common contact for NO and NC 5 NC Alarm relay NC Normal Close output Operating input voltages 8 60VDC Power consumption 2W max 24V 3W...

Страница 13: ...unction on RJ 45 Standard IEEE 802 3af PD Powered Device Power classification Class 3 Working voltage 36V 57V Pin assignment RJ 45 PoE power pins Pin PoE IN 1 2 3 4 V 5 V 6 7 V 8 V Mechanical Dimension 95 x 80 x 40 mm Case HxDxW Housing Enclosed metal with no fan Mounting Din rail mounting Panel mounting optional Environmental Operating Temperature Typical 30 70 Storage Temperature 40 85 Relative ...

Страница 14: ... 14 CE EMC Class A VCCI Class A Safety LVD IEC 60950 1 ...

Страница 15: ...unplug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any objects into the openings o...

Страница 16: ...287BInstall the mounting bracket onto the switch unit as shown below KSC 361 S2 RS 232 model KSC 361 S4 RS 422 485 model 2 1288BAttach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the bracket can clamp on the upper edge of the DIN rail 3 1289BClamp the unit to the DIN rail and make sure it is mounted securely KSC 361 S2 RS 232 model KSC 361 S4 RS 422 485 mo...

Страница 17: ... 17 Dimensions KSC 361 S2 RS 232 model KSC 361 S4 RS 422 485 model ...

Страница 18: ...h on a plane surface securely The mounting steps are 1 1290BInstall the mounting bracket on the switch unit KSC 361 S2 RS 232 model KSC 361 S4 RS 422 485 model 2 1291BScrew the bracket on the switch unit 3 1292BScrew the device on a panel Two screw locations red cross are shown below KSC 361 S2 RS 232 model KSC 361 S4 RS 422 485 model ...

Страница 19: ... 19 Dimensions KSC 361 S2 RS 232 model KSC 361 S4 RS 422 485 model ...

Страница 20: ...er PoE RJ 45 36VDC 57VDC Remote PoE PSE device over Cat 5 Caution Do not use more than one power input type at the same time Two power inputs will cause damage to the device Use just one among the three power inputs for your installation 173B2 5 1 Direct Power via Terminal Block Power pins of the terminal block connector Pin 1 Vdc negative input terminal 2 Vdc positive input terminal A 5P terminal...

Страница 21: ...pecifications Polarity center positive Center contact 2 0mm Outer contact 6 3mm Voltage rating 8 30VDC Note that most of the AC DC power adapters in the market are provided for commercial use generally Check the environment conditions before use it Contact your dealers for the availability of industrial rated power adapter ...

Страница 22: ...PD Input voltage range 36V 57V Pins to receive power Vpoe Pin 4 5 Vpoe Pin 7 8 Connect PoE mid span injector over Cat 5 cable The following figure uses RS 232 model as example The same connection can be for RS 422 485 model too Connect PoE end span PSE Ethernet switch port The following figure uses RS 232 model as example The same connection can be for RS 422 485 model too ...

Страница 23: ...mal Open contacts Open Normal Shorted Alarm NO NO Pin 4 5 Alarm relay output NC Normal Closed contacts Shorted Normal Open Alarm NC NC Either pair can be used depending on the logic requirement for the relay monitoring system Use the provided 3P terminal plug for signal wiring and plug into the contacts Alarm Events Input power failure Ethernet port link down Enabled by software TCP server connect...

Страница 24: ... Check whether the network is recovered The button can also be used to restore the software configuration settings to factory default values The operations are Operation Function Press the button and release when ALARM LED blinking ALARM LED is blinking until boot up finished ALARM becomes OFF Reset boot up the device The behavior is same as power boot procedure Press the button until ALARM LED be...

Страница 25: ...implifies the cable installation Auto negotiation Function The port is featured with auto negotiation function and full capability to support connection to any Ethernet devices The port performs a negotiation process for the speed and duplex configuration with the connected device automatically when each time a link is being established If the connected device is also auto negotiation capable both...

Страница 26: ...ber transceiver into the SFP slot Normally a bail is provided for every SFP transceiver Hold the bail and make insertion 3 Until the SFP transceiver is seated securely in the slot place the bail in lock position Connecting Fiber Cables LC connectors are commonly equipped on most SFP transceivers Identify TX and RX connector before making cable connection Make sure the Rx to Tx connection rule is f...

Страница 27: ...ches KSC 361 S2 RS 232 model SW Name Setting Function 1 CM ON Serial port serves console configuration OFF Serial port serves standard functions 2 RSD Reserved KSC 361 S4 RS 422 485 model SW Name Setting Function 1 CM ON Serial port serves console configuration OFF Serial port serves standard functions 2 2W 4W ON 2 wire bus TX B connects RX B internally OFF 4 wire bus 3 2W 4W ON 2 wire bus TX A co...

Страница 28: ...2 wire and 4 wire topology Refer to Appendix for more information about RS 422 RS 485 standards and 2 wire 4 wire topology 2 11 2 Receiver Terminator RTM ON setting enables the internal 120 ohms terminator on the receiver interface A proper termination is important in a bus topology or multi drop network The terminator is a resistor added in parallel with the receiver s A and B lines in order to m...

Страница 29: ...as The line bias is used to maintain the proper idle state voltage to the idle condition when no driver is enabled on the bus These bias resistors are pull up resistors on the data B line and pull down resistors to ground on data A line In 4 wire configuration the bias resistors are placed on the receiver lines RX B1 B2 OFF disables the internal BIAS resistors on receiver lines RX B1 B2 ON setting...

Страница 30: ...2 interface Male DB9 DTE The connection is illustrated as follows 2 12 1 Making PC Connection via COM Port Device s RS 232 interface Male DB9 DTE PC COM ports Male DB9 DTE RS 232 cable Null modem without handshaking female DB9 to female DB9 ...

Страница 31: ...trates the device connects a LAN via Cat 5 or fiber cable alternatively and a 2 wire serial bus topology 2 14 Making RS 485 4 Wire Connection The figure below illustrates the device connects a LAN via Cat 5 or fiber cable alternatively and a 4 wire serial bus topology ...

Страница 32: ...nk Tx or Rx on serial port OFF No data traffic PoE PoE power status Green ON The device is powered by PoE input OFF No PoE input FX Fiber SFP Green ON SFP is selected and active for Ethernet port OFF SFP is not selected ALARM Alarm status Green ON Alarm event occurred Blink When the device boot up OFF No alarm event LAN Ethernet port status Green ON Port link up no traffic Blink Port activity OFF ...

Страница 33: ... illustrated as follows The serial interface can be RS 232 or RS 422 485 bus which more serial devices are connected depending on the product model is used To enable this application model the Windows PC must be installed with a software program called VCOM which is bundled in the product package s CD Refer to Appendix 2 for more information ...

Страница 34: ...two serial devices communicate over a LAN remotely 3 3 Serial Server Mode The converter is featured with a mode which the device operates as a serial server Under this mode the device forwards the serial data stream received from a client over TCP IP network to the serial interface ...

Страница 35: ...slave converters can be up to 10 3 5 Reverse Telnet Mode The converter s reverse telnet mode allows a PC host to access another device s console port serial port through the converter remotely over a network as illustrated below The device may be a modem LAN switch a router or any with AUX port Telnet is initiated from the PC and the converter operates as a server for the telnet connection It forw...

Страница 36: ...ctory defaults The password is required for local authentication in accessing to the device via Http web based interface For security reason it is recommended to change the default settings for the device before deploying it to your network 4 2 Configuring IP Address Password via console Setting SW CM ON will set the Serial Port to Console Mode for configuration The configuration commands are at s...

Страница 37: ...ter password in the login page Default password 123 Click Apply to login into the converter Web Page after a Successful Login Use System Host page to configure IP address and password for the device Click Apply to save the configuration changes Use Reboot System command to reboot the device and make the changes effective Refer to Chapter5 Web Management for the details ...

Страница 38: ... Web Management 5 1 Login Factory default password 123 Note that the user is requested to make a login again when the inactivity timeout 10 minutes is expired with no user s operation in Web UI 5 2 Main Menu ...

Страница 39: ...ogical identification designated to this device Password Password setting for Login authentication Confirm Password Re enter the password if it is changed IP Address The IP address designated to this device when static IP mode is used Subnet Mask The IP subnet mask of this device Default Gateway The IP address of the default gateway used by this device DNS Server The IP address of the DNS server u...

Страница 40: ...Serial Server One TCP server device as the serial server One TCP client device Use TCP Control Remote COM One TCP server device Windows PC installed with VCOM as TCP client Use TCP Control Serial Broadcasting One UDP master device One or more up to 10 UDP slave devices Use UDP Control Reverse Telnet One TCP server device PC host running telnet as a client Use TCP Control Advanced Allow the maximum...

Страница 41: ...g Mode Server This converter will operate as a TCP server Client This converter will operate as a TCP client Disable TCP communication is disabled Remote Server The IP address of the remote server to which this client is planned to connect Client s setting Domain Name Domain name is allowed if the exact IP address of the remote server is unknown Client Keep Connected Check to enable the client to ...

Страница 42: ...ing when it is in idle state Client s setting The message can notify the remote server that the client is still alive and just in idle state Server Alive Time TCP connection is closed if there is no TCP activity in the given time duration Keep alive message will reset the time count Server s setting Apply Click to save the changes ...

Страница 43: ... The web UI will give minimum settings required for the selected application The applications provided are Pair Connection Two converters connected over a LAN are used to extend the distance between two serial devices Serial Server Remote COM Serial Broadcast Reverse Telnet Refer to Chapter 3 for description of each application mode ...

Страница 44: ...e There are Master device and Slave devices involved in this application Each is provided with different configuration interface as shown in following two sections 5 6 1 UDP Master Configuration Configuration Description Application Change another matched application if you need a simplified configuration ...

Страница 45: ...er UDP port number to which the master sends data to the salve over UDP Apply Click to save the changes Note The changes will be effective after next device s boot up 5 6 2 UDP Slave Configuration Configuration Description Application Change another matched application if you need a simplified configuration Operation Mode Master The master sends received serial data stream to all slave devices ove...

Страница 46: ...bit is asserted space the parity bit is un asserted Stop Bits The stop bits configured for the serial port Options 1 Default 1 5 for data 5 bits or 2 Packing Rules Any data received from the serial port will be stored in an RX queue first before it is forwarded to LAN port The packing rules are used in operation how the packed data in RX queue is forwarded to LAN port Packing Size The size limit o...

Страница 47: ...ceived Del 1 forward when one more byte is received after delimiters Del 2 forward when two more bytes are received after delimiters Del stripped forward when delimiters are received but delimiters are removed Del Code 1 The first delimiter code that is required in selected delimiter rule Disabled Default Del Code 2 The second delimiter code that is required in selected delimiter rule Disabled Def...

Страница 48: ...tocol complaint Email Enabled Check to enable Email notification Port Number The port number used in SMTP port 25 is default value Server Address Email server address Login Information Login settings for the Email server Authentication Is Authentication required Username Username for login Password Password for login Mail To Email addresses to which the notification mail is sent 200 characters max...

Страница 49: ...boot by web UI command LAN Port Link Up Link up on LAN port AuthenticationFailure Web Authentication failed in web login Password Changed Authentication password is changed IP Address Changed IP configuration is changed Include change to DHCP TCP Connection Failed TCP connection is failed Apply Click to save the changes 5 9 Statistic Overview Status Description TCP Connection Status Current state ...

Страница 50: ...etwork It is a specific method for sending messages from one device to another as part of troubleshooting IP network connections A ping test determines whether your device can communicate with another device across a network In cases where network communication is successfully established ping tests also can determine the connection latency a technical term for connection delay between the two dev...

Страница 51: ...after this command 5 13 Firmware Update Firmware update operation is divided into several steps as follows 1 Confirm update request 2 Warning message is displayed 3 Erasing flash firmware code image running messages Note http 192 168 0 177 is just an example In real case it shows IP address of your device 4 Browse and select the firmware image file for uploading after flash is erased completely ...

Страница 52: ... Web login page Note In the case that the device was powered down accidentally during erasing flash you may turn the device on to let it enter Step 3 to complete the Erasing flash procedure In the case that the device was powered down accidentally after erasing flash completed but uploading image not completed you may turn the device on to let it enter Step 4 to complete the firmware image uploadi...

Страница 53: ... 53 5 14 Logout Click Yes to confirm logout ...

Страница 54: ...on the PC 4 Console output system information as below KSC 361 Ethernet to Serial Converter CPU PHY Check OK MAC Address 00 40 f6 d1 00 02 DHCP Client Disabled IP Address 192 168 0 177 Subnet Mask 255 255 255 0 Gateway Address 192 168 0 1 DNS Address 192 168 0 1 LAN Port Media Auto Operation Mode TCP server Serial Port Baud Rate 230400 bps Console Mode Enabled S W Version v1 00 Beta 20170315 pm161...

Страница 55: ... at set sys ar lpld ld ld enabled disabled Alarm relay event LAN port link down at set sys ar tcp scf cf cf enabled disabled Alarm relay event TCP connection failure TCP Control Command Set Command Options Description at set application ap ap advanced pair connection serial server remote com serial broadcast reverse telnet Application mode at set operation mode mode mode disabled tcp client tcp se...

Страница 56: ...name at set udp rs pn p n p port number 1 65535 n 1 10 slave ID UDP slave port number Serial Control Command Set Command Options Description at set sp baudrate br br 300 1200 2400 4800 9600 19200 38400 57600 115200 230400 Baudrate at set sp data bits db db 5 6 7 8 Data bits at set sp parity bits pb pb odd even none space mark Parity bits at set sp stop bits sb sb 1 2 Stop bits at set sp pr ps ps p...

Страница 57: ...rs as listed below They did not standardize such things such as cables and connectors pin outs bus arbitration signaling protocols or physical wiring topology Many different implementations have come into use and they are often incompatible with each other Characteristics RS 422 RS 485 Mode of operation Differential Differential Unidirectional Full Duplex Multipoint Multipoint Allowed no of Tx and...

Страница 58: ...twork In this topology there is only one driver sending to one or more receivers One termination resistor is recommended at the extreme end of the bus to eliminate reflections Up to 10 receivers are permitted under RS 422 Multiple receive only nodes may be used for point to multipoint communications A1 3 RS 485 Multi drop Network This topology is similar to RS 422 multi drop However up to 32 recei...

Страница 59: ...ould be terminated at both ends to prevent reflections Only one node can drive the bus at a time making this a half duplex communication channel Only one driver should be active at any one time Therefore the transceivers used on a half duplex bus should support a Driver Enable function A1 5 RS 485 Full duplex 4 wire Network The 4 wire network simplifies bus arbitration in multi node RS 485 A singl...

Страница 60: ...gy It allows the converter to be compatible with most of existing serial applications for Windows A2 1 Functions of VCOM The purpose of VCOM 1 Search Device 2 Create Remove Configure Virtual Com ports A2 2 Installing the VCOM Program The software is called VCOM utility for windows2000 xp 2003 2008 Vista Windows 7 x86 x64 However it is also compatible to Windows 8 and Windows 10 The steps for insta...

Страница 61: ... 61 3 Follow the steps for WinPcap installation 4 Installation complete ...

Страница 62: ...OM provides Device Info and COM Mapping operations as follows Device Info Two buttons are provided to 1 Search Click to search all VCOM compatible devices in network 2 Search by IP Click to search the devices in the specified IP ranges ...

Страница 63: ...ate a COM mapping Select the target device for your mapping from the search list Delete COM Mapping Specify the existing COM port number to be deleted first in the list Click to remove the specified COM port mapping from the list ...

Страница 64: ...d in Main menu as illustrated below to get VCOM enabled to auto start for Windows A2 4 Alternative Solution beside VCOM Program Refer to https www eltima com products serial over ethernet for professional solution with similar features provided by VCOM program ...